Purpose: Semiconductor detectors are increasingly considered as alternatives to scintillation crystals for nuclear imaging applications such as positron emission tomography (PET) or single photon emission computed tomography (SPECT). One of the most prominent detector materials is cadmium zinc telluride (CZT), which is currently used in several application-specific nuclear imaging systems. In this work, the charge-transport effects in pixelated CZT detectors in relation to detector pixel size and thickness are investigated for pixels sizes from 0.4 up to 1.6 mm.

Methods: The determination of an optimum pixel size and thickness for use with photon energies of 140 and 511 keV, suitable for SPECT and PET studies, is attempted using photon detection efficiency and energy resolution as figures of merit. The Monte Carlo method combined with detailed finite element analysis was utilized to realistically model photon interactions in the detector and the signal generation process. The GEANT4 Application for Tomographic Emission (GATE) toolkit was used for photon irradiation and interaction simulations. The COMSOL MULTIPHYSICS software application was used to create finite element models of the detector that included charge drift, diffusion, trapping, and generation. Data obtained from the two methods were combined to generate accurate signal induction at the detector pixels. The energy resolution was calculated as the full width at half maximum of the energy spectrum photopeak. Photon detection efficiency was also calculated. The effects of charge transport within the detector and photon escape from primary pixel of interaction were investigated; the extent of diffusion to lateral pixels was also assessed.

Results: Charge transport and signal induction were affected by the position of a pixel in the detector. Edge and corner pixels were less susceptible to lateral diffusion than pixels located in the inner part of the detector. Higher detection efficiency and increased photon escape from primary interaction pixel were observed for thicker detectors. Energy resolution achieved better values in 0.7 and 1.0 mm pixel size for 5 mm detector thickness and 1.6 mm pixel size for 10 mm thickness.

Conclusions: Selection of pixel size and thickness depends on the imaging application and photon energy utilized. For systems that integrate two nuclear imaging modalities (i.e., combined SPECT/PET), the pixel size should offer an appropriate balance of the effects that take place in the detector, based on the results of the current work. This allows for a system to be designed with the same detector material and the same geometrical configuration for both modalities.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.3532825DOI Listing

Publication Analysis

Top Keywords

pixel size
24
energy resolution
16
detection efficiency
16
nuclear imaging
12
size thickness
12
detector
11
photon
9
pixel
9
monte carlo
8
charge-transport effects
8

Similar Publications

Mass spectrometry (MS) is a valuable tool that enables label-free analysis and the ability to measure multiple molecules. The atmospheric pressure MS imaging (MSI) method usually requires tedious sample preparation. A simple ionization method with minimal sample preparation is needed for high-throughput analysis.

View Article and Find Full Text PDF

Accurate diagnosis of pancreatic cancer using CT scan images is critical for early detection and treatment, potentially saving numerous lives globally. Manual identification of pancreatic tumors by radiologists is challenging and time-consuming due to the complex nature of CT scan images and variations in tumor shape, size, and location of the pancreatic tumor also make it challenging to detect and classify different types of tumors. Thus, to address this challenge we proposed a four-stage framework of computer-aided diagnosis systems.

View Article and Find Full Text PDF

The Effect of Window Size on Pathologists' Search for Rare Elements in a Digital Pathology Setting.

Arch Pathol Lab Med

January 2025

From the Department of Medical Biophysics (Lopes, Ward) and Pathology and Laboratory Medicine, Schulich School of Medicine and Dentistry (Rasmussen, Djordjevic, Gomez, Mora, Sharma, Walsh, Wehrli, Cecchini), and the Departments of Pathology (Cecchini), and Oncology (Ward), Western University, London, Ontario, Canada.

Context.—: Digital pathology requires pathologists to assess tissue digitally rather than on an analog microscope, which has been the mainstay tool for tissue assessment for more than a century. The impact of different digital interaction configurations on pathologists' performance is not well understood.

View Article and Find Full Text PDF

Carbon fiber reinforced polymers (CFRPs) are widely used in fields such as aviation and aerospace. However, subtle defects can significantly impact the material's service life, making defect detection a critical priority. In this paper, delamination defects in CFRP are detected using line laser infrared thermography, and a defect characterization algorithm that combines differential thermography with a frequency-domain filter is proposed.

View Article and Find Full Text PDF

Predicting pack-ice seal occupancy of ice floes along the Western Antarctic Peninsula.

PLoS One

December 2024

Department of Ecology and Evolution, Stony Brook University, Stony Brook, New York, United States of America.

We explore the habitat use of Antarctic pack-ice seals by analyzing their occupancy patterns on pack-ice floes, employing a novel combination of segmented generalized linear regression and fine-scale (∼ 50 cm pixel resolution) sea ice feature extraction in satellite imagery. Our analysis of environmental factors identified ice floe size, fine-scale sea ice concentration and nearby marine topography as significantly correlated with seal haul out abundance. Further analysis between seal abundance and ice floe size identified pronounced shifts in the relationship between the number of seals hauled out and floe size, with a positive relationship up to approximately 50 m2 that diminishes for larger floe sizes and largely plateaus after 500 m2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!