Effect of hydraulic retention time on the performance of down-flow hanging sponge system treating grey wastewater.

Bioprocess Biosyst Eng

School of Energy Resources and Environmental Engineering, Egypt-Japan University of Science and Technology (E-Just), P.O. Box 179, New Borg El Arab City, Alexandria, 21934, Egypt.

Published: August 2011

Grey wastewater (GW) treatment via down-flow hanging sponge (DHS) system was the subject of the study. The reactor was operated at different hydraulic retention times (HRTs) of 11.7, 5.8 and 2.9 h, corresponding to organic loading rates (OLRs) of 1.9, 3.6 and 6.8 kgCOD/m3 day, respectively. The results obtained revealed that decreasing the HRT from 11.7 to 2.9 h negatively affected on the performance of the DHS system. COD(total), COD(soluble), COD(particulate) and detergent removal efficiency were reduced from 96 ± 2.4 to 90 ± 2.3%, from 83 ± 10 to 69 ± 8%, from 98 ± 2 to 94 ± 3% and from 96 ± 12 to 88 ± 6.9%, respectively. However, the removal efficiency of the distinguished COD fractions and detergent remained unaffected when decreasing the HRT from 11.7 to 5.8 h. The DHS system provided a removal efficiency of 95 ± 1% for COD(total), 79 ± 8% for COD(soluble), 98 ± 2 for COD(particulate) and 94.7% for detergent at an HRT of 5.8 h. Based on these results, it is recommended to operate such a system at an HRT of 5.8 h and OLR not exceeding 3.6 kgCOD/m3 day for producing an effluent quality complying for reuse in unrestricted irrigation purposes. The removal of TKj-N and nitrification efficiency in the DHS system was significantly affected by increasing the OLR from 1.9 to 3.6 kgCOD/m3 day and from 3.6 to 6.8 kgCOD/m3 day. At an OLR of 1.9 kgCOD/m3 day, the DHS system removed 80 ± 12% of TKj-N and 91 ± 22% of ammonia which is significantly higher than that at an OLR of 3.6 (58.5 ± 13%) and 6.8 kgCOD/m3 day (26.8 ± 16%). Similar results were recorded for the removal of total coliform (TC), viz., the efficiencies dropped for TC from 99.8 ± 0.2 to 99.4 ± 0.8% and from 99.4 ± 0.8 to 90.0 ± 7.6%, respectively. DHS profile results showed that the major part of COD was removed in the upper portion of the system while the nitrification process was taken place in the lower part of the DHS system at OLR of 1.9 kgCOD/m3 day and HRT of 11.7 h.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00449-011-0528-9DOI Listing

Publication Analysis

Top Keywords

kgcod/m3 day
28
dhs system
24
hrt 117
12
removal efficiency
12
olr kgcod/m3
12
system
9
hydraulic retention
8
down-flow hanging
8
hanging sponge
8
grey wastewater
8

Similar Publications

Post-treatment of anaerobic effluent by ozone and ozone/UV of a kraft cellulose pulp mill.

Water Sci Technol

October 2015

Department of Hydraulic and Sanitary Engineering, São Carlos School of Engineering, University of São Paulo, Av Trabalhador Saocarlense 400, São Carlos, SP, Brazil.

Pulp and paper mill effluents represent a challenge when treatment technologies are considered, not only to reduce organic matter, but also to reduce the toxicological effects. Although anaerobic treatment has shown promising results, as well as advantages when compared with an aerobic system, this process alone is not sufficient to reduce recalcitrant compounds. Thus, an advanced oxidation process was applied.

View Article and Find Full Text PDF

Modelling anaerobic digestion processes is a key aspect of studying and optimizing digesters and related waste streams. However, for the satisfactory prediction of biogas production and effluent characteristics, some parameters have to be calibrated according to the characteristics of the substrates. This article describes a calibration procedure for the IWA 'Anaerobic Digestion Model no.

View Article and Find Full Text PDF

Effect of hydraulic retention time on the performance of down-flow hanging sponge system treating grey wastewater.

Bioprocess Biosyst Eng

August 2011

School of Energy Resources and Environmental Engineering, Egypt-Japan University of Science and Technology (E-Just), P.O. Box 179, New Borg El Arab City, Alexandria, 21934, Egypt.

Grey wastewater (GW) treatment via down-flow hanging sponge (DHS) system was the subject of the study. The reactor was operated at different hydraulic retention times (HRTs) of 11.7, 5.

View Article and Find Full Text PDF

The effect of vinyl acetate in acetoclastic methanogenesis.

Bioresour Technol

January 2011

Universidad Autónoma Metropolitana, Biotechnology Dept., P.A. 55-535, 09340 Iztapalapa, México D.F., Mexico.

The influence of vinyl acetate (VA) in the methanogenesis was evaluated, by using an upflow anaerobic sludge blanket reactor of 1.5L. The reactor was operated at 33.

View Article and Find Full Text PDF

A Submerged Membrane Anaerobic Reactor (SMAR) is being developed for the treatment of waste water originating in Sasol's coal to fuel synthesis process. The laboratory-scale SMAR uses A4-size submerged flat panel ultrafiltration membranes to induce a 100% solids-liquid separation. Biogas gets extracted from the headspace above the anaerobic mixed liquor and reintroduced through a coarse bubble diffuser below the membranes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!