Cup arthroplasty is a conservative bone-sparing option for resurfacing of the humeral head. Earlier reports have shown its effectiveness in appropriately selected patients with osteoarthritis, osteonecrosis, and severe rheumatoid arthritis. Patients with cuff tear arthropathy may also benefit from a modified cup arthroplasty technique. The purpose of this article is to describe the surgical technique involved in humeral cup arthroplasty in cuff tear arthropathy patients. We will review the indications, contraindications, complications, and postoperative rehabilitation.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BTH.0b013e3181e5d9abDOI Listing

Publication Analysis

Top Keywords

cup arthroplasty
16
cuff tear
12
tear arthropathy
12
cup
4
arthroplasty rotator
4
rotator cuff
4
arthropathy cup
4
arthroplasty conservative
4
conservative bone-sparing
4
bone-sparing option
4

Similar Publications

Wear particle reaction is present in every arthroplasty. Sometimes, this reaction may lead to formation of large pseudotumors. As illustrated in this case, the volume of the reaction may be out of proportion to the volume of the wear scar.

View Article and Find Full Text PDF

Objective: To determine the feasibility, yield, and safety of fluoroscopic-guided aspiration of the acutely dislocated total hip arthroplasty (AD-THA).

Materials And Methods: IRB-approved, retrospective review of fluoroscopic-guided aspirations of AD-THA (January 2005-December 2023) was performed. Data from electronic charts and fluoroscopy images/reports were obtained.

View Article and Find Full Text PDF

Introduction: The RM Pressfit vitamys is an uncemented, titanium particle-coated, isoelastic monoblock cup made of vitamin E blended highly cross-linked polyethylene. We addressed the following questions: (1) What are the clinical and (2) radiographic outcomes 10 years after implantation? (3) What is the revision rate?

Methods: In this prospective observational study in a tertiary care centre we investigated all consecutive cases of total hip replacement with the RM Pressfit vitamys cup between September 2009 and November 2011. It was implanted in 162 hips, 49.

View Article and Find Full Text PDF

Background: Proper positioning of a total hip arthroplasty (THA) plays a crucial role in the success and long-term survivorship of the implant. Cup positioning within the Lewinnek Safe Zone (LSZ) does not, however, avoid implant dislocation. Thus, the concept of a functional cup position has been introduced.

View Article and Find Full Text PDF

The 'Japanese paradox' of total hip arthroplasty: where are we going?

Expert Rev Med Devices

January 2025

Department of Orthopaedic Surgery, Kansai Medical University, Hirakata, Osaka, Japan.

Introduction: There is a worldwide trend toward 'revisiting' cemented total hip arthroplasty (THA). In Japan, however, cemented THAs accounts for 11%, and the percentage of cemented hemiarthroplasty is estimated to be less than 10%. This review was designed to reconsider the option of cemented THA and to encourage policy changes in Japan to support the best possible care for patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!