A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel liquid chromatographic method for simultaneous estimation of pioglitazone and glimepiride in rat plasma by solid phase extraction: application to preclinical pharmacokinetic studies. | LitMetric

The need for a reliable bioanalytical method is of primary importance during preclinical studies. The aim of the present study was simultaneous determination of pioglitazone (CAS 111025-46-8) (PIO) and glimepiride (CAS 93479-97-1) (GLM) in plasma of rats. A high-performance liquid chromatographic method has been developed and validated using C18 column and UV detector. A mobile phase composed of acetonitrile and ammonium acetate buffer pH 4.5 in the ratio of 55:45%. The plasma samples clean-up was carried out using solid phase cartridges. The method was in the linear range of 50-8000 ng/mL for PIO and 50-2000 ng/mL for GLM. The coefficient of regression was found to be > or = 0.99. Precision and accuracy were within the acceptable limits, as indicated by relative standard deviation varying from 1.5 to 6.1% for PIO and 3.1 to 7.0% for GLM whereas the accuracy ranged from 97.0 to 106.4% for PIO and 96.5 to 106.4% for GLM. The mean extraction recovery was found to be 90.2 +/- 4.5, 76.8 +/- 2.8 and 85.2 +/- 5.2% for PIO, GLM and internal standard, respectively. Moreover, PIO and GLM were stable in plasma, up to 30 days of storage at -70 degrees C and after being subjected to bench top, auto-sampler, and three freeze-thaw cycles. The developed method was applied for preclinical pharmacokinetic studies.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0031-1296164DOI Listing

Publication Analysis

Top Keywords

liquid chromatographic
8
chromatographic method
8
solid phase
8
preclinical pharmacokinetic
8
pharmacokinetic studies
8
pio glm
8
pio
6
glm
6
method
5
novel liquid
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!