A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Minimum-step immuno-analysis based on continuous recycling of the capture antibody. | LitMetric

Minimum-step immuno-analysis based on continuous recycling of the capture antibody.

Analyst

Program for Bio-Microsystem Technology, Korea University, 204C Specific Research Wing, Biotechnology Building (Green Campus), 1, 5-ka, Anam-dong, Sungbuk-gu, Seoul, 136-701, Republic of Korea.

Published: April 2011

Most immuno-analytical systems employ antibodies that do not readily dissociate upon binding to its partner antigen (i.e., target analyte; α2-macroglobulin as a model) and, thus, either need to be disposed of after one-time use or be reused after binding has been reset. To achieve a minimum-step analysis, an antibody that is capable of rapidly reversible binding with high affinity to an antigen was investigated in this study. This antibody was immobilized on the surface of a label-free sensor, which was combined with microfluidic channels, to demonstrate its applicability. The antibody was successively reused without a regeneration step under physiological conditions, offered specific analysis in the serum medium, and detected the analyte at concentrations as low as 0.1 ng mL(-1), which could further be enhanced by 100-fold. The sensor response reached 95% equilibrium after 8.3 and 14.9 min in average on each dose level for the concentration increase and decrease, respectively. The dynamic range covered a 5 logarithmic analyte concentration. Since the sampling size was in the nanolitre to millilitre range per day under the conditions used and the sensor may retain a long shelf-life, it could potentially be used in a clinical setting for long-term, on-line monitoring of diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c0an00811gDOI Listing

Publication Analysis

Top Keywords

minimum-step immuno-analysis
4
immuno-analysis based
4
based continuous
4
continuous recycling
4
recycling capture
4
antibody
4
capture antibody
4
antibody immuno-analytical
4
immuno-analytical systems
4
systems employ
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!