A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Evaluation of a new, microfluidic chip-based immunoassay for measurement of AFP-L3]. | LitMetric

Purpose: AFP-L3 is an isoform of a-fetoprotein which has a fucosylated carbohydrate chain, and the fraction of AFP-L3/total AFP (AFP-L3%) specifically increases in hepatocellular carcinoma (HCC) patients and is widely used for screening and prognosis of HCC. The newly developed microTAS method which combines microchip electrophoresis and lectin affinity electrophoresis can rapidly provide AFP-L3% and total AFP measurements simultaneously at higher sensitivity. Here, we evaluated the system to know its analytical performance and clinical utility.

Method: Fully automated immunoanalyzer, microTASWako i30 which utilizes Liquid-phase Binding Assay-Electrokinetic Analyte Transport Assay (LBA-EATA method) as the assay principle was employed for the measurement of total AFP and AFP-L3%. We evaluated detection sensitivity, precision, accuracy, and correlation of the method.

Results: The detection sensitivity was 0.3 ng/ml for both AFP-L1 and L3. The accuracy of the assay was 91.3-105.0% for total AFP. The precision of the assay was CV 1.9% at 2 ng/ml of total AFP, and CV 1.3% for 10% of AFP-L3% at 20ng/ml of total AFP. The microTAS method showed good correlation with the lectin affinity electrophoresis (AFP-L3 Test Wako) and the LBA methods (LBA Wako AFP-L3 on LiBASys) methods, giving correlation coefficient (r) of 0.988 and 0.988, respectively. The microTAS immunoreaction assay time and the total assay time including chip preparation were 1 and 9 min, respectively.

Conclusion: Since the microchip assay is rapid and highly sensitive, it should have better clinical utility than the current methods.

Download full-text PDF

Source

Publication Analysis

Top Keywords

total afp
20
afp afp-l3%
8
microtas method
8
lectin affinity
8
affinity electrophoresis
8
detection sensitivity
8
assay time
8
assay
7
afp
6
total
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!