Due to its small size and versatility, the biarsenical-tetracysteine system is an attractive way to label viral proteins for live cell imaging. This study describes the genetic labeling of the human immunodeficiency virus type 1 (HIV-1) structural proteins (matrix, capsid and nucleocapsid), enzymes (protease, reverse transcriptase, RNAse H and integrase) and envelope glycoprotein 120 with a tetracysteine tag in the context of a full-length virus. We measure the impact of these modifications on the natural virus infection and, most importantly, present the first infectious HIV-1 construct containing a fluorescently-labeled nucleocapsid protein. Furthermore, due to the high background levels normally associated with the labeling of tetracysteine-tagged proteins we have also optimized a metabolic labeling system that produces infectious virus containing the natural envelope glycoproteins and specifically labeled tetracysteine-tagged proteins that can easily be detected after virus infection of T-lymphocytes. This approach can be adapted to other viral systems for the visualization of the interplay between virus and host cell during infection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3037950PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0017016PLOS

Publication Analysis

Top Keywords

biarsenical-tetracysteine system
8
virus infection
8
tetracysteine-tagged proteins
8
virus
6
proteins
5
labeling
4
labeling multiple
4
multiple hiv-1
4
hiv-1 proteins
4
proteins biarsenical-tetracysteine
4

Similar Publications

Real-time imaging of viruses in living cells considerably facilitates the study of virus-host interactions. However, generating a fluorescently labeled recombinant virus is challenging, especially for Zika virus (ZIKV), which causes microcephaly in neonates. The monocistronic nature of the ZIKV genome represents a major challenge for generating a replication-competent genetically engineered ZIKV suitable for real-time imaging.

View Article and Find Full Text PDF

How FlAsH got its sparkle: historical recollections of the biarsenical-tetracysteine tag.

Methods Mol Biol

September 2015

Independent Researcher, 4470 Arch Street, San Diego, CA, USA,

The biarsenical-tetracysteine tagging system was the first of (and inspiration for) the now numerous methods for site-specifically labeling proteins in living cells with small molecules such as fluorophores. This historical recollection describes its conception and the trial-and-error chemical development required to become a versatile technique.

View Article and Find Full Text PDF

Due to its small size and versatility, the biarsenical-tetracysteine system is an attractive way to label viral proteins for live cell imaging. This study describes the genetic labeling of the human immunodeficiency virus type 1 (HIV-1) structural proteins (matrix, capsid and nucleocapsid), enzymes (protease, reverse transcriptase, RNAse H and integrase) and envelope glycoprotein 120 with a tetracysteine tag in the context of a full-length virus. We measure the impact of these modifications on the natural virus infection and, most importantly, present the first infectious HIV-1 construct containing a fluorescently-labeled nucleocapsid protein.

View Article and Find Full Text PDF

Rapid FlAsH labelling in the budding yeast Saccharomyces cerevisiae.

J Microsc

October 2010

Mitochondrial Structure and Dynamics Group, Department of NanoBiophotonics, Max Planck Institute for Biophysical Chemistry, Göttingen, Germany.

Live cell imaging of protein distributions is an essential tool in modern cell biology. It relies on the functional labelling of a host protein with a fluorophore, which may either be a genetically fused fluorescent protein or an organic dye binding to the host protein. The biarsenical-tetracysteine system or 'FlAsH-labelling', is based on the high affinity interaction between a biarsenical probe and a small protein tag.

View Article and Find Full Text PDF

Non-perturbing and site-specific protein labeling methods are highly desired as they allow researchers to probe complex cellular functions. The biarsenical/tetracysteine labeling system allows in situ fluorescent labeling of intracellular proteins which have been appended with small (12 amino acids) genetically encoded peptide tags. In this work we present the selection of semi-randomized tandem tetracysteine peptides with improved biarsenical (ReAsH) fluorescent brightness (~2-fold) relative to a single tetracysteine motif or rationally designed 3-fold tetracysteine repeat.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!