Text classifiers have been used for biosurveillance tasks to identify patients with diseases or conditions of interest. When compared to a clinical reference standard of 280 cases of Acute Respiratory Infection (ARI), a text classifier consisting of simple rules and NegEx plus string matching for specific concepts of interest produced 569 (4%) false positive (FP) cases. Using instance level manual annotation we estimate the prevalence of contextual attributes and error types leading to FP cases. Errors were due to (1) Deletion errors from abbreviations, spelling mistakes and missing synonyms (57%); (2) Insertion errors from templated document structures such as check boxes, and lists of signs and symptoms (36%) and; (3) Substitution errors from irrelevant concepts and alternate meanings for the same word (6%). We demonstrate that specific concept attributes contribute to false positive cases. These results will inform modifications and adaptations to improve text classifier performance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3041533PMC

Publication Analysis

Top Keywords

false positive
12
text classifier
12
acute respiratory
8
respiratory infection
8
positive cases
8
errors
5
analysis false
4
positive errors
4
errors acute
4
text
4

Similar Publications

Background: Ochratoxin A (OTA) is toxic secondary metabolites produced by fungi and can pose a serious threat to food safety and human health. Due to the high stability and toxicity, OTA contamination in agricultural products is of great concern. Therefore, the development of a highly sensitive and reliable OTA detection method is crucial to ensure food safety.

View Article and Find Full Text PDF

Engineering thermostable fluorescent DNA aptamer for the isothermal amplification of nucleic acids.

Biosens Bioelectron

January 2025

Key Laboratory of Laboratory Medical Diagnostics, Ministry of Education, Department of Laboratory Medicine, Chongqing Medical University, Chongqing, China. Electronic address:

Isothermal amplification-based nucleic acid detection technologies have become rapid and efficient tools for molecular diagnostics. Sequence-specific monitoring methods are crucial for isothermal amplification, as they help identify the occurrence of extended primer dimers, which can lead to false positive results. Fluorescent aptamers are promising tools for real-time monitoring of isothermal amplification but are inherently limited by thermostability.

View Article and Find Full Text PDF

Resonance SERS probe based on the bifunctional molecule IR808 combined with SA test strips for highly sensitive detection of monkeypox virus.

Spectrochim Acta A Mol Biomol Spectrosc

January 2025

Clinical Research Institute, Department of Laboratory Medicine, The First Affiliated Hospital of Xiamen University, School of Medicine, College of Chemistry and Chemical Engineering, College of Energy, College of Physical Science and Technology, and Discipline of Intelligent Instrument and Equipment, Xiamen University, Xiamen 361005 China; Scientific Research Foundation of State Key Laboratory of Vaccines for Infectious Diseases, Xiang An Biomedicine Laboratory, Xiamen 361005 China. Electronic address:

As a zoonotic virus, highly sensitive detection of monkeypox virus is crucial for its prevention and control due to its rapid increase in cases worldwide and the extremely high risk of virus transmission. In this paper, based on the principle of antigen-antibody specific recognition, an ultrasensitive resonance Raman biosensing probe was prepared using a molecule with the bifunctionality of resonance Raman effect and capturing antibody; and with the strong affinity of the biotin-streptavidin (Bio-SA) system, Bio-antibody and SA test strips were prepared. To match the T-line of the test strip, a portable Raman instrument with a strip-shaped spot was designed.

View Article and Find Full Text PDF

Despite its low incidence in Europe, rubella's immune status is still routinely assessed using commercial immunoassays. However, some discrepancies have been observed between these tests and the Immunoblot. The main objective of this study is to evaluate, by a commercial immunoblot, the immune status of a female population that had previously presented negative, low-positive, or equivocal rubella IgG with a commercial immunoassay.

View Article and Find Full Text PDF

Purpose: Mortality and morbidity of patients with bloodstream infection (BSI) remain high despite advances in diagnostic methods and efforts to speed up reporting. This study investigated the impact of reporting rapid Minimum Inhibitory Concentration (MIC)-results in Gram negative BSIs with the ASTar system (Q-linea, Uppsala, Sweden) on the adaptation of empirically started antimicrobial therapy. We performed a real-world study during which antimicrobial susceptibility testing (AST) results were instantly reported to the treating physician in an established multidisciplinary antimicrobial stewardship setting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!