Phosphate binders include calcium acetate or carbonate, sevelamer hydrochloride or carbonate, magnesium and lanthanum carbonate, and aluminum carbonate or hydroxide. Their relative phosphate-binding capacity has been assessed in human, in vivo studies that have measured phosphate recovery from stool and/or changes in urinary phosphate excretion or that have compared pairs of different binders where dose of binder in each group was titrated to a target level of serum phosphate. The relative phosphate-binding coefficient (RPBC) based on weight of each binder can be estimated relative to calcium carbonate, the latter being set to 1.0. A systematic review of these studies gave the following estimated RPBC: for elemental lanthanum, 2.0, for sevelamer hydrochloride or carbonate 0.75, for calcium acetate 1.0, for anhydrous magnesium carbonate 1.7, and for "heavy" or hydrated, magnesium carbonate 1.3. Estimated RPBC for aluminum-containing binders were 1.5 for aluminum hydroxide and 1.9 for aluminum carbonate. The phosphate-binding equivalent dose was then defined as the dose of each binder in g × its RPBC, which would be the binding ability of an equivalent weight of calcium carbonate. The phosphate-binding equivalent dose may be useful in comparing changes in phosphate binder prescription over time when multiple binders are being prescribed, when estimating an initial binder prescription, and also in phosphate kinetic modeling.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1525-139X.2011.00849.xDOI Listing

Publication Analysis

Top Keywords

equivalent dose
12
carbonate
10
phosphate binder
8
calcium acetate
8
sevelamer hydrochloride
8
hydrochloride carbonate
8
aluminum carbonate
8
relative phosphate-binding
8
dose binder
8
calcium carbonate
8

Similar Publications

Background: Surgical intervention is critical in the treatment of hip developmental dysplasia in children. Perioperative analgesia, usually based on high opioid dosages, is frequently used in these patients. In some circumstances, regional anesthetic procedures such as caudal block and lumbar plexus block have also been used.

View Article and Find Full Text PDF

A systematic review of the effectiveness of leaded glasses for ensuring safety among healthcare professionals in fluoroscopy.

J Med Imaging Radiat Sci

January 2025

Instituto Politécnico de Coimbra, ESTESC - Coimbra Health School, Medical Imaging and Radiotherapy, Rua 5 de Outubro, S. Martinho do Bispo, Coimbra 3046-854, Portugal. Electronic address:

Background: Currently, there is an increase in procedures across various clinical specialties involving the use of ionising radiation.

Objective: The primary objective of this systematic review is to analyse and compare the existing literature regarding the effectiveness of leaded glasses for healthcare professionals.

Methods: Comprehensive literature searches were conducted for relevant studies published between 2018 and 2023 using the Scopus, PubMed, and Web of Science databases according to preferred reporting items for systematic reviews and meta-analyses (PRISMA) methodology.

View Article and Find Full Text PDF

Objective: The purpose of this study was to present a newly designed 3D-printed personalized model (3D PPM) of a radiofrequency needle guide with a maxillary fixation for gasserian ganglion (GG) puncture.

Methods: Implementation of 3D CT-guided radiofrequency therapy of the GG with and without use of 3D PPM was analyzed. The following parameters were assessed: radiation time, dose area product, air kerma reference point, pain severity during the puncture needle insertion, prosopalgia regression degree (according to visual analog scale) and the severity of facial numbness (according to the Barrow Neurological Institute scale) in the early postoperative period, and postpuncture complications.

View Article and Find Full Text PDF

Sepiapterin is an exogenously synthesized new chemical entity that is structurally equivalent to endogenous sepiapterin, a biological precursor of tetrahydrobiopterin (BH), which is a cofactor for phenylalanine hydroxylase. Sepiapterin is being developed for the treatment of hyperphenylalaninemia in pediatric and adult patients with phenylketonuria (PKU). This study employed concentration-QT interval analysis to assess QT prolongation risk following sepiapterin treatment.

View Article and Find Full Text PDF

Eye lens dosimetry: does the direction of rotation (vertical or horizontal) play a role in type testing?

J Radiol Prot

January 2025

Radiation Protection Dosimetry (6.3), Physikalisch-Technische Bundesanstalt, Braunschweig, NDS, GERMANY.

With the International Commission on Radiological Protection (ICRP) lowering the annual dose limit for the eye lens to 20 mSv, precise monitoring of eye lens exposure has become essential. The personal dose equivalent at a depth of 3 mm, Hp(3), is the measurement method for monitoring the dose to the lens of the eye. Traditional dosimetry methods primarily address lateral radiation exposure scenarios, where radiation approaches from the left or right, necessitating the rotation of the phantom during type testing around the vertical axis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!