An MR-electrophysiology (EP) catheter is presented that provides full diagnostic EP functionality and a high level of radiofrequency safety achieved by custom-designed transmission lines. Highly resistive wires transmit intracardiac electrograms and currents for intracardiac pacing. A transformer cable transmits the localization signal of a tip coil. Specific absorption rate simulations and temperature measurements at 1.5 T demonstrate that a wire resistance > 3 kΩ/m limits dielectric heating to a physiologically irrelevant level. Additional wires do not increase tip specific absorption rate significantly, which is important because some clinical catheters require up to 20 electrodes. It is further demonstrated that radiofrequency-induced and pacing-induced resistive heating of the wires is negligible under clinical conditions. The MR-EP catheters provided uncompromised recording of electrograms and cardiac pacing in combination with a standard EP recorder in MR-guided in vivo EP studies, and the tip coil enabled fast and robust catheter localization. In vivo temperature measurements during such a study did not detect any device-related heating, which confirms the high level of safety of the catheter, whereas unacceptable heating was found with a standard EP catheter. The presented concept for the first time enables catheters with full diagnostic EP functionality and active tracking and at the same time a sufficient level of radiofrequency safety for MRI without specific absorption rate-related limitations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3715087 | PMC |
http://dx.doi.org/10.1002/mrm.22669 | DOI Listing |
Aesthetic Plast Surg
January 2025
Department of Plastic Surgery, The First Affiliated Hospital of Fujian Medical University, No. 20, Chazhong Road, Taijiang District, Fuzhou, China.
Bromhidrosis significantly impacts individuals' social, professional, and emotional well-being. Traditional treatments such as en bloc excision and alcohol injections are now less favored due to associated complications and suboptimal outcomes. Current evidence identifies botulinum toxin A (BTX-A) as the first-line treatment for mild to moderate cases (Grade 0-2), attributed to its high efficacy, excellent safety profile, and minimally invasive nature.
View Article and Find Full Text PDFIntroduction: Endoscopic ablation is the mainstay treatment for dysplastic Barrett's esophagus (BE), of which radiofrequency ablation (RFA) and argon plasma coagulation (APC) are the most widely available options.
Objectives: We aimed to analyze the safety and outcomes of endoscopic ablation for BE within Polish centers.
Patients And Methods: We retrospectively analyzed data from three high-volume endoscopy units between 2002-2024.
Nat Rev Cardiol
January 2025
Division of Cardiology, Columbia University Irving Medical Center, New York, NY, USA.
Innovative therapies for hypertension are desperately needed given the rising prevalence and falling rates of control of hypertension despite an abundance of available medical therapies. Procedural interventions lower blood pressure without depending on adherence to medications, and endovascular renal denervation (RDN) is the interventional procedure with the best evidence base for the treatment of hypertension. After nearly two decades of study, with major refinements to devices, technique and trial design, two different systems for RDN received approval from the FDA in late 2023 for the treatment of hypertension.
View Article and Find Full Text PDFEnviron Int
December 2024
Department of Oncology and Molecular Medicine, National Institute of Health (Istituto Superiore di Sanità), Rome, Italy(2).
PLoS One
December 2024
Department of Gastroenterology, The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Chinese Medicine), Hangzhou, Zhejiang.
Endoscopic antireflux therapy is widely used in clinical practice. Peroral endoscopic cardial constriction (PECC), antireflux mucosal intervention (ARMI), and radiofrequency ablation (RF) possess analogous antireflux mechanisms. This comprehensive systematic review and meta-analysis aimed to evaluate and compare the safety and effectiveness of antireflux therapy during endoscopic cardia peripheral tissue scar formation (ECSF) procedures.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!