In cervical multi-level degenerative pathology, considering the morbidity of the extensive fusion techniques, some authors advocate for the multilevel disc replacement. This study compared the safety and efficacy of disc replacement with an unconstrained prosthesis in multi- versus single-level patients. A total of 231 patients with cervical degenerative disc disease (DDD) who were treated with cervical disc replacement and completed their 24 months follow-up were analyzed prospectively: 175 were treated at one level, 56 at 2 levels or more. Comparison between both groups was based on usual clinical and radiological outcomes [Neck Disability Index (NDI), Visual Analog Scale (VAS), Range of Motion, satisfaction]. Safety assessments, including complication and subsequent surgeries, were also documented and compared. Mean NDI and VAS scores for neck and arm pain were improved in both groups similarly. Improvement of mobility at treated segments was also similar. Nevertheless, in the multi-level group, analgesic use was significantly higher and occurrence of Heterotopic Ossification significantly lower than in the single-level group. Subject satisfaction was nearly equal, as 94.2% of single-level group patients would undergo the surgery again versus 94.5% in the multi-level group. The overall success rate did not differ significantly. Multi-level DDD is a challenging indication in the cervical spine. This study showed no major significant clinical difference between the two groups. We need further studies to know more about the impact of multi-level arthroplasty, especially on the adjacent segments, but these results demonstrate initial safety and effectiveness in this patient sample.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3175911 | PMC |
http://dx.doi.org/10.1007/s00586-011-1722-9 | DOI Listing |
BMC Oral Health
January 2025
Faculty of Dentistry, Department of Restorative Dentistry, Gazi University, Bişkek St. 1. St. Number: 8 Emek, Ankara, Turkey.
Background: Repairing composite resins is a less invasive alternative to complete restoration replacement. To achieve a successful bond between the existing and newly applied composite materials, various surface preparation methods, such as sandblasting and acid etching, have been explored. The aim of the study was to evaluate the effect of different surface treatments on the repair bond strength of a universal nanohybrid composite resin restorative material before and after thermal aging, by utilizing a micro-shear bond strength (µSBS) test.
View Article and Find Full Text PDFSpine (Phila Pa 1976)
January 2025
Department of Orthopaedics, Xijing Hospital, Air Force Medical University, Xi'an China.
Study Design/setting: A retrospective cohort study.
Objective: To compare long-term outcomes and complications of cervical disc replacement (CDR) and anterior cervical discectomy and fusion (ACDF) with cage-plate constructs (CPC) and stand-alone (SA) cages in treating degenerative cervical spondylosis.
Summary Of Background Data: ACDF is commonly used for cervical radiculopathy but may increase adjacent segment degeneration (ASD).
J Spine Surg
December 2024
Spinal Surgery Team, Wirbelsäulenzentrum Ostschweiz AG, St. Gallen, Switzerland.
Background: The objective of this report is to present a case of two cervical spine artificial discs (Bryan Cervical Disk) that completely disappeared within 6 months as a result of a high-energy trauma more than 10 years after the initial surgery. Implant dislocation is a known complication in artificial cervical disc replacement. However, this report presents the case of an exceptional migration path with esophageal ingrowth and rectal excretion, not only for one artificial disc but for two at different times It highlights the need for long-term follow-up examinations after artificial cervical disc arthroplasty (ACDA).
View Article and Find Full Text PDFOestrogen and progesterone fluctuate cyclically in women throughout their adult lives. Although these hormones cross the blood-retinal barrier and bind to intraocular receptors, their effects remain unclear. We present the first review to date on associations between posterior pole structures-specifically the macula, choroid, and optic disc-and both the menstrual cycle and post-menopausal period, utilising multimodal imaging techniques in healthy adult non-pregnant women.
View Article and Find Full Text PDFClin Spine Surg
January 2025
Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL.
Study Design: Retrospective study.
Objective: We aim to determine the influence of preoperative Patient-Reported Outcome Measurement Information System Physical Function (PROMIS-PF) scores on perioperative and postoperative outcomes, the latter determined through patient-reported outcome measures (PROMs) and the degree of achievement rates of minimum clinically important difference (MCID) following single-level cervical disc replacement (CDR).
Background: Several studies have examined the relationship between preoperative PROMIS-PF as a prognostic factor for postoperative outcomes.