A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A simulation-based comparison of two methods for determining relaxation rates from relaxometry images. | LitMetric

When assessing liver iron content using relaxometry, an average relaxation rate (R1, R2 or R2*) is usually determined from a region of interest or the entire liver. This is commonly performed by fitting the signal decay in individual voxels to an appropriate relaxation function. The voxel-level parameters resulting from the fits are combined to determine the average relaxation rate, and an empirically derived calibration curve is used to convert this single value to iron content. The goal of this study was to compare the precision and accuracy of this voxel-wise fitting to an alternative method that relies on first averaging the signals from all voxels within the region of interest and then determining the relaxation rate from a single fit. Systematic differences were observed when both methods were applied to clinical images. Mathematical simulations were employed to determine which method provided more robust estimates of the true relaxation rate. The mathematical simulations were then expanded to include a range of conditions expected in typical relaxometry images. The results show that voxel-wise fitting skews the relaxation rate estimates and increases variance, particularly when the true relaxation rate is moderate to fast, as it would be in liver with high iron content. The potential impact of these results on clinical decisions is discussed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3078944PMC
http://dx.doi.org/10.1016/j.mri.2010.11.005DOI Listing

Publication Analysis

Top Keywords

relaxation rate
24
iron content
12
relaxation
8
determining relaxation
8
relaxometry images
8
average relaxation
8
region interest
8
voxel-wise fitting
8
mathematical simulations
8
true relaxation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!