Objective: The aim of this clinical trial was to compare primary and secondary stability of implants placed by bone condensing versus the standard drilling technique in the posterior edentulous maxilla.

Study Design: Forty-eight SLA Straumann implants 4.1 × 10 mm (Institut Straumann AG, Waldenburg, Switzerland) were placed into edentulous maxillary posterior region in the same positions bilaterally, using the bone condensation technique for one and the standard technique for the other side. Implant stability measurements were performed immediately after implant placement, as well as every week for the next 6 weeks by use of resonance frequency analysis (RFA). Data were analyzed using Mann-Whitney U and Wilcoxon tests.

Results: After bone condensing, significantly higher implant stability was recorded immediately after surgery as well as during the whole observation period of 6 weeks compared with bone-drilling technique (Mann-Whitney U test, P = .000).

Conclusions: The bone-condensing technique can be recommended as an alternate surgical approach for implant site preparation in reduced bone density to achieve greater implant stability in the posterior maxilla.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.tripleo.2010.11.010DOI Listing

Publication Analysis

Top Keywords

implant stability
16
stability posterior
8
posterior maxilla
8
bone condensing
8
implant
6
technique
5
posterior
4
maxilla bone-condensing
4
bone-condensing versus
4
versus bone-drilling
4

Similar Publications

Inferior outcome of stand-alone short versus long tibial stem in revision total knee arthroplasty. A retrospective comparative study with minimum 2 year follow-up.

SICOT J

January 2025

Department of Orthopedic Surgery and Sport Medicine, Croix-Rousse Hospital, FIFA Medical Center of Excellence, 69004 Lyon, France - Université de Lyon, Université Claude Bernard Lyon 1, IFSTTAR, LBMC UMR_T9406, 69622 Lyon, France.

Introduction: Revision Total Knee Arthroplasty (RTKA) is complex, and induced bone loss might endanger implant fixation and joint stability. Intramedullary stems improve fixation throughout stress redistribution. The current study aims to compare the performance of short tibial stems with long tibial stems, investigating their intermediate-term radiographic and survival outcomes in RTKA.

View Article and Find Full Text PDF

Mandibular Reconstruction With a Patient-Specific Implant Following Surgical Excision of an Acanthomatous Ameloblastoma in a Dog.

J Vet Dent

January 2025

Department of Dentistry, Oral and Maxillo-facial Surgery, Eastcott Veterinary Referrals, Part of Linnaeus Group, Swindon, UK.

Canine acanthomatous ameloblastoma (CAA) is an invasive benign epithelial odontogenic tumour most commonly affecting the mandible of large breed dogs. To the author's knowledge, this report describes the first computer-aided design patient-specific implant (PSI) that has been placed for a critical sized bone defect in mandibular reconstruction of a dog in the UK. The aim was to restore mandibular stability using a regenerative approach combining a titanium locking plate and compression-resistant matrix infused with recombinant human bone morphogenetic protein-2 (rhBMP-2) to bridge the 85 mm mandibular defect created by a segmental mandibulectomy.

View Article and Find Full Text PDF

This study investigates the mechanical properties as well as and cyto- and biocompatibility of collagen membranes cross-linked with glutaraldehyde (GA), proanthocyanidins (PC), hexamethylendiisocyanate (HMDI) and 1-Ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxysuccinimide (EC/NHS). A non-crosslinked membrane was used as reference control (RF). The initial cytotoxic analyses revealed that the PC, EC, and HMDI crosslinked membranes were cytocompatible, while the GA crosslinked membrane was cytotoxic and thus selected as positive control in the further study.

View Article and Find Full Text PDF

Biomechanical comparison of the efficacy of Cfr-PEEK and titanium systems in the fixation following sagittal split advancement osteotomy: a biomechanical study.

BMC Oral Health

January 2025

Department of Oral and Maxillofacial Surgery, Ordu University, Cumhuriyet Yerleşkesi Cumhuriyet Mahallesi, 52200, Ordu, Türkiye, Turkey.

Background: This study evaluates the efficacy of carbon fiber reinforced Polyetheretherketone (Cfr-PEEK) in fixation after sagittal split ramus osteotomy (SSRO) by comparing it with titanium in vitro.

Methods: Twenty-eight sheep hemimandibles were randomly assigned to four groups for SSRO surgery. Fixation was performed with a 4-hole titanium mini plate for 5 mm advancement in Group 1, with a 4-hole Cfr-PEEK mini plate for 5 mm advancement for Group 2, with a 4-hole titanium mini plate for 10 mm advancement for Group 3, and with a 4-hole Cfr-PEEK mini plate for 10 mm advancement for Group 4.

View Article and Find Full Text PDF

S-palmitoylation is a reversible and widespread post-translational modification, but its role in the regulation of ferroptosis has been poorly understood. Here, we elucidate that GPX4, an essential regulator of ferroptosis, is reversibly palmitoylated on cysteine 66. The acyltransferase ZDHHC20 palmitoylates GPX4 and increases its protein stability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!