Background And Aims: Angio-embolisation in trauma is a relatively new technique that is gaining popularity and recognition in identifying and arresting bleeding in trauma patients. We studied the possibility whether angio-embolisation using the Digital Subtraction Angiography (DSA), in the operating theatre (OT) could achieve successful haemostasis in trauma patients. We further studied the feasibility of using this technique as part of trauma resuscitation/damage control.

Methods: A retrospective study of trauma patients, with Injury Severity Score (ISS ≥ 9), admitted to Tan Tock Seng Hospital (TTSH) from January 2004 to December 2008 was done. Patients who had received angio-embolisation in the OT or angiography suite were evaluated in terms of age, gender, ISS, the site and type of angioembolisation used. The primary end point was to assess the success rate of angioembolisation using the C-Arm DSA in the OT, and whether there were any complications necessitating a repeat procedure or surgical intervention. The secondary end points of the study were aimed at studying the cost effectiveness of this technique, logistical feasibility and evaluating this technique as part of the initial trauma resuscitative efforts.

Results: A total of 43 trauma patients received angioembolisation. 32 patients had the angio-embolisation done using the C-Arm DSA in the OT (n = 32). None of the patients who received angioembolisation in the operating theatre (n = 32) had any re-bleeding. 15 out of 32 survived. There were no complications related to the angio-embolisation procedure. The majority of angio-embolisations done were for pelvic fractures.

Conclusion: The success of angio-embolisation in the OT using the C-Arm DSA for a trauma patient and its complication rates are similar to that done in a dedicated angio-graphic suite. We conclude that angio-embolisation in the operating theatre using the C-Arm DSA is feasible, cost effective and can be a modality in the initial trauma resuscitation/damage control in any lead lined operating theatre. We believe that we are the first to describe this method of angio-embolisation using the C-Arm DSA in a conventional lead lined trauma operating theatre and its use as a feasible option in a trauma resuscitation/damage control algorithm.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2011.01.026DOI Listing

Publication Analysis

Top Keywords

operating theatre
24
trauma patients
20
c-arm dsa
20
trauma
12
trauma resuscitation/damage
12
patients received
12
angio-embolisation c-arm
12
angio-embolisation operating
8
patients
8
digital subtraction
8

Similar Publications

Climate change is an emerging global health crisis, disproportionately affecting low- and middle-income countries (LMICs) where health outcomes are increasingly compromised by environmental stressors such as pollution, natural disasters, and human migration. With a focus on promoting health equity, Global Surgery advocates for expanding access to surgical care and enhancing health outcomes, particularly in resource-limited and disaster-affected areas like LMICs. The healthcare industry-and more specifically, surgical care-significantly contributes to the global carbon footprint, primarily through resource-intensive settings, i.

View Article and Find Full Text PDF

The Theatre Safety Club 2024 took place on 6 November in London and on 26 November in Newcastle. The CPDcertified event aimed to educate and provide insight into safety in the operating theatre, boasting an impressive line-up of speakers and sessions that were well attended. The conference was sponsored by Cardinal Health, a leading healthcare company providing value-based product solutions, with a comprehensive portfolio covering mechanical thromboprophylaxis, nutritional insufficiency solutions, thermometry and surgical gloves.

View Article and Find Full Text PDF

Descemet's membrane (DM) detachment is a significant, if rare, risk of intracameral injection of viscoelastic to treat hypotony after glaucoma filtration surgery. We describe two cases of DM detachment following inadvertent injection of viscoelastic into the posterior stroma and the techniques used for their repair. In both cases, conventional air tamponade failed to resolve the detachment, and further surgical intervention was required.

View Article and Find Full Text PDF

Background: Inhalational anesthetic agents are a major source of potent greenhouse gases in the medical sector, and reducing their emissions is a readily addressable goal. Nitrous oxide (NO) has a long environmental half-life relative to carbon dioxide combined with a low clinical potency, leading to relatively large amounts of NO being stored in cryogenic tanks and H cylinders for use, increasing the chance of pollution through leaks. Building on previous findings, Stanford Health Care's (SHC's) NO emissions were analyzed at 2 campuses and targeted for waste reduction as a precursor to system-wide reductions.

View Article and Find Full Text PDF

Enriching surgical theatre competence through computer-based simulation.

Radiography (Lond)

January 2025

UniSA Allied Health & Human Performance, University of South Australia, Adelaide, SA 5001, Australia.

Introduction: Radiographers support the multidisciplinary team by facilitating medical imaging within the operating theatre environment. This project aimed to enhance student readiness for clinical competency in operative theatre imaging by implementing an authentic C-arm simulator for students to use prior to attending clinical placement.

Methods: This study followed a pre-post, quantitative study design.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!