A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Separation behavior of U(VI) and Th(IV) on a cation exchange column using 2,6-pyridine dicarboxylic acid as a complexing agent and its application for the rapid separation and determination of U and Th by ion chromatography. | LitMetric

AI Article Synopsis

  • The study focused on how well uranium (U) and thorium (Th) stick to a cation exchange column when combined with a specific acid (PDCA) at low pH.
  • A new ion chromatography method was created to quickly separate U and Th using a specific eluent, allowing both elements to elute in less than 2 minutes.
  • The method showed high precision, low detection limits for U and Th, and was successfully applied to test for these elements in wastewater samples.

Article Abstract

The retention behavior of U and Th as their 2,6-pyridine dicarboxylic acid (PDCA) complexes on a cation exchange column was investigated under low pH conditions. Based on the observed retention characteristics, an ion chromatographic method for the rapid separation of uranium and thorium in isocratic elution mode using 0.08 mM PDCA and 0.24 M KNO(3) in 0.22 M HNO(3) as the eluent was developed. Both uranium and thorium were eluted as their PDCA complexes within 2 min, whereas the transition and lanthanide metal cations were eluted as an unresolved broad peak after thorium. Under the optimized conditions both U and Th have no interference either from alkali and alkaline earth elements up to a concentration ratio of 1:500 or from other elements up to 1:100. The detection limits (LOD) of U and Th were calculated as 0.04 and 0.06 ppm, respectively (S/N=3). The precision in the measurement of peak area of 0.5 ppm of both U and Th was better than 5% and a linear calibration in the concentration range of 0.25-25 ppm of U and Th was obtained. The method was successfully applied to determine U and Th in effluent water samples.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.201000907DOI Listing

Publication Analysis

Top Keywords

cation exchange
8
exchange column
8
26-pyridine dicarboxylic
8
dicarboxylic acid
8
rapid separation
8
pdca complexes
8
uranium thorium
8
separation behavior
4
behavior uvi
4
uvi thiv
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!