A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid genotyping of human papillomavirus by post-PCR array-based hybridization techniques. | LitMetric

Rapid genotyping of human papillomavirus by post-PCR array-based hybridization techniques.

J Clin Microbiol

Philips Research Europe, Department of Molecular Diagnostics, High Tech Campus 12a, 5656 AE Eindhoven, Netherlands.

Published: April 2011

Kinetic hybridization measurements on a microarray are expected to become a valuable tool for genotyping applications. A method has been developed that enables kinetic hybridization measurements of PCR products on a low-density microarray. This is accomplished by pumping a solution containing PCR products up and down through a porous microarray substrate. After every pumping cycle, the fluorescently labeled PCR products hybridized to capture probes immobilized on the solid surface of the porous microarray substrate are measured. By this method, both binding curves and high-resolution melting curves are obtained instead of the single endpoint hybridization intensities as with commonly used post-PCR array-based hybridization techniques. We used 20 subtypes of the human papillomavirus (HPV) as a model system to test our detection method and blindly analyzed 216 clinical samples. We compared our microarray flowthrough method with a reference method, PCR followed by a reverse line blot (RLB). Real-time hybridization measurements followed by high-resolution melting curves of low concentrations of fluorescently labeled HPV targets on a microarray were successfully carried out without any additional chemical signal amplification. The results of our new method were in good agreement (93%, with a kappa coefficient of κ = 0.88 [95% CI, 0.81 to 0.94]) with the RLB results. All discrepant samples were analyzed by a third method, enzyme immunoassay (EIA). Furthermore, in a number of cases, we were able to identify false-positive samples by making use of the information contained in the kinetic binding and melting curves. This clearly demonstrates the added value of the use of kinetic measurements and high-resolution melting curves, especially for highly homologous targets.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3122796PMC
http://dx.doi.org/10.1128/JCM.01606-10DOI Listing

Publication Analysis

Top Keywords

melting curves
16
hybridization measurements
12
pcr products
12
high-resolution melting
12
human papillomavirus
8
post-pcr array-based
8
array-based hybridization
8
hybridization techniques
8
kinetic hybridization
8
porous microarray
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!