Computer navigation in total knee arthroplasty produces better component alignment than conventional techniques. Different navigation systems exist. We undertook a prospective, randomized study comparing 2 navigations systems (Stryker Full Navigation and Stryker Articular Surface Mounted [ASM] navigation systems). Three-dimensional component alignment (Perth computed tomographic knee protocol) and function at 1 year (Knee Society Scores) were assessed. Forty patients participated (20 fully navigated and 20 ASM-navigated total knee arthroplasties). Cohorts were well matched according to sex, age, and body mass index. No statistically significant difference was seen in any parameter of 3-dimensional component alignment or function between cohorts. Operative time for the ASM cohort was significantly less than the fully navigated cohort (P = .001). Both systems performed equally well, and therefore, surgeon preference should determine which system is used.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2010.12.022DOI Listing

Publication Analysis

Top Keywords

component alignment
16
total knee
12
navigation systems
12
three-dimensional component
8
knee arthroplasty
8
prospective randomized
8
randomized study
8
study comparing
8
fully navigated
8
knee
5

Similar Publications