A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Study to determine the clinical significance of HEmolysis During Orbital AtheRectomy (CLEAR study). | LitMetric

Purpose: To evaluate the incidence of clinically evident hemolysis associated with orbital atherectomy used to treat severe peripheral artery disease.

Methods: The observational CLEAR study enrolled 31 subjects (16 men; mean age 71 ± 10 years, range 44-92) with claudication (58.1%) or critical limb ischemia (38.7%) who underwent orbital atherectomy with the Diamondback 360 system at 4 US centers. The 42 lesions in 31 limbs were located in the superficial femoral (n = 19, 45.2%), popliteal (n = 8, 19.0%), and tibial arteries (n = 15, 35.8%). The majority of lesions (34, 81.0%) were de novo; moderate or severe calcification was identified in 90.5% of cases. Lesion and procedural parameters were analyzed at a core laboratory. Blood samples were collected during and post procedure and analyzed for markers of hemolysis. The primary endpoint was the occurrence of clinically significant hemolysis. The secondary endpoints included the occurrence of any clinical symptoms/signs potentially related to hemolysis. Statistical analysis was performed to identify predictors for hemolysis.

Results: Laboratory evidence of hemolysis was seen in 11 (35.5%) subjects. No one met the clinical event criteria, and so the primary endpoint of the study was not reached. The secondary endpoints were hypertensive crisis (1, 3.2%) and transient hemoglobinuria (3, 9.7%). Lower glomerular filtration rates, calcified plaque, long atherectomy runs, and solid crown selection were independent predictors of hemolysis.

Conclusion: There was no clinically significant hemolysis after orbital atherectomy. The results of this study will enable users to predict conditions that predispose to high levels of red cell hemolysis following orbital atherectomy and to take appropriate measures to limit its occurrence.

Download full-text PDF

Source
http://dx.doi.org/10.1583/10-3179.1DOI Listing

Publication Analysis

Top Keywords

orbital atherectomy
20
hemolysis orbital
12
hemolysis
8
clear study
8
primary endpoint
8
clinically hemolysis
8
secondary endpoints
8
atherectomy
6
study
5
orbital
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!