A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Internal and external validation strategies for the evaluation of long-term effects in NIR calibration models. | LitMetric

Some of the practical aspects of long-term calibration-set building are presented in this study. A calibration model able to predict the Kolbach index for brewing malt is defined, and four different validations and resampling schemes were applied to determine its real predictive power. The results obtained demonstrated that one single performance criterion might be not sufficient and can lead to over- or underestimation of the model quality. Comparing a simple leave-one-sample-out cross-validation (CV) with two more challenging CVs with leave-N-samples-out, where the resamplings were repeated 200 times, it is demonstrated that the error of prediction value has an uncertainty, and these values change according to the type and the number of validation samples. Then, two kinds of test-set validations were applied, using data blocks based on the sample collection's year, demonstrating that it is necessary to consider long-term effects on NIR calibrations and to be conservative in the number of factors selected. The conclusion is that one should be modest in reporting the prediction error because it changes according to the type of validation used to estimate it and it is necessary to consider the long-term effects.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jf104439xDOI Listing

Publication Analysis

Top Keywords

long-term effects
12
effects nir
8
consider long-term
8
internal external
4
external validation
4
validation strategies
4
strategies evaluation
4
long-term
4
evaluation long-term
4
nir calibration
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!