Characterization of the transport and release of phospholipids from a silicone hydrogel contact lens is required to assess the possible use of these lenses for phospholipid delivery to increase patient comfort. Contact lenses of silicone hydrogel composition were loaded with varying amounts of radiolabeled 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC) from a solution of n-propanol. These lenses were eluted at 35°C into artificial tear fluid (ATF) or ATF containing varying amounts of DMPC. The amount of DMPC loaded into a lens is a linear function of the time of exposure to the DMPC/propanol solution. The initial rate of elution into ATF appears to be diffusion controlled for at least 10 h and is proportional to the amount of DMPC loaded. The elution rate decreases as the DMPC concentration in the ATF increases. The ease of loading and the controllable release of DMPC from silicone hydrogels presents the possibility of using such lenses to counter eye discomfort caused by inherently low levels of phospholipid in tears.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1163/092050611X554174 | DOI Listing |
Water Environ Res
January 2025
Zhejiang Key Laboratory of Petrochemical Environmental Pollution Control, Zhejiang Ocean University, Zhoushan, P. R. China.
The discharge of oil-laden wastewater from industrial processes and the frequent occurrence of oil spills pose severe threats to the ecological environment and human health. Membrane materials with special wettability have garnered attention for their ability to achieve efficient oil-water separation by leveraging the differences in wettability at the oil-water interface. These materials are characterized by their simplicity, energy efficiency, environmental friendliness, and reusability.
View Article and Find Full Text PDF3D Print Med
January 2025
Department of Surgical & Interventional Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
Background: Penile implant surgery is the standard surgical treatment for end-stage erectile dysfunction. However, the growing complexity of modern high-tech penile prostheses has increased the demand for more practical training opportunities. The most advanced contemporary training methods involve simulation training using cadavers, with costs exceeding $5,000 per cadaver, inclusive of biohazard fees.
View Article and Find Full Text PDFClin Exp Optom
January 2025
Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Manchester, UK.
Clinical Relevance: Knowledge of contact lens prescribing trends can (a) assist practitioners to benchmark their own prescribing habits, (b) help the contact lens industry understand preferred products, and (c) support academics in scholarly writings.
Background: This work aims to document contact lens prescribing trends in Australia over the past quarter of a century.
Methods: An annual survey of contact lens prescribing trends was conducted in Australia each year from 2000 to 2024, inclusive, by asking optometrists to provide information relating to 10 consecutive contact lens fits undertaken between January and March.
Turk J Ophthalmol
December 2024
Muğla Sıtkı Koçman University Faculty of Medicine, Department of Ophthalmology, Muğla, Türkiye.
Objectives: To compare the efficacy of two different silicone hydrogel bandage contact lenses (BCLs) in terms of visual rehabilitation and ocular discomfort following photorefractive keratectomy (PRK).
Materials And Methods: This prospective study included 60 eyes of 30 patients who underwent bilateral PRK surgery to correct myopia and/or astigmatism refractive errors. Following surgery, lotrafilcon A BCLs were applied to the right eye and senofilcon A BCLs were applied to the left eye.
J Funct Biomater
December 2024
Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada.
Intraocular lenses (IOLs) play a pivotal role in restoring vision following cataract surgery. The evolution of polymeric biomaterials has been central to addressing challenges such as biocompatibility, optical clarity, mechanical stability, and resistance to opacification. This review explores essential requirements for IOL biomaterials, emphasizing their ability to mitigate complications like posterior capsule opacification (PCO) and dysphotopsias while maintaining long-term durability and visual quality.