Background: Colorectal cancer is the second most common tumor in developed countries, with a lifetime prevalence of 5%. About one third of these tumors are located in the rectum. Surgery in terms of low anterior resection with mesorectal excision is the central element in the treatment of rectal cancer being the only option for definite cure. Creating a protective diverting stoma prevents complications like anastomotic failure and meanwhile is the standard procedure. Bowel obstruction is one of the main and the clinically and economically most relevant complication following closure of loop ileostomy. The best surgical technique for closure of loop ileostomy has not been defined yet.
Methods/design: A study protocol was developed on the basis of the only randomized controlled mono-center trial to solve clinical equipoise concerning the optimal surgical technique for closure of loop ileostomy after low anterior resection due to rectal cancer.The HASTA trial is a multi-center pragmatic randomized controlled surgical trial with two parallel groups to compare hand-suture versus stapling for closure of loop ileostomy. It will include 334 randomized patients undergoing closure of loop ileostomy after low anterior resection with protective ileostomy due to rectal cancer in approximately 20 centers consisting of German hospitals of all level of health care. The primary endpoint is the rate of bowel obstruction within 30 days after ileostomy closure. In addition, a set of surgical and general variables including quality of life will be analyzed with a follow-up of 12 months. An investigators meeting with a practical session will help to minimize performance bias and enforce protocol adherence. Centers are monitored centrally as well as on-site before and during recruitment phase to assure inclusion, treatment and follow up according to the protocol.
Discussion: Aim of the HASTA trial is to evaluate the efficacy of hand-suture versus stapling for closure of loop ileostomy in patients with rectal cancer.
Trial Registration: German Clinical Trial Register Number: DRKS00000040.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3042950 | PMC |
http://dx.doi.org/10.1186/1745-6215-12-34 | DOI Listing |
PLoS One
January 2025
Changchun University of Science and Technology, School of Optoelectronic Engineering, Changchun, Jilin, China.
Accurate localization is a critical technology for the application of intelligent robots and automation systems in complex indoor environments. Traditional visual SLAM (Simultaneous Localization and Mapping) techniques often face challenges with localization accuracy in high similarity scenes. To address this issue, this paper proposes an improved visual SLAM loop closure detection algorithm that integrates deep learning techniques.
View Article and Find Full Text PDFSurg Endosc
January 2025
Department of General Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, 277 Yanta West Road, Xi'an, 710061, Shaanxi, China.
Background: The traditional method of prophylactic loop ileostomy is time-consuming and prone to complications like stoma stenosis, peristomal adhesions, or dermatitis. The aim of this study is to evaluate the clinical application value and potential benefits of a novel approach named linea alba support method (LASM) of prophylactic loop ileostomy via lower abdominal midline incision.
Methods: The clinical data of rectal cancer patients admitted to the General Surgery Department of the First Affiliated Hospital of Xi'an Jiaotong University between January 2021 and December 2023 were retrospectively analyzed.
Langmuir
January 2025
Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Bio-functional Materials, Department of Materials Science and Engineering, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, P. R. China.
Steric stabilization and lubrication give loop polymer brushes enhanced antifouling properties. In the study, linear zwitterionic poly(NMASMCMS) brushes were first constructed on a poly(ethylene terephthalate) (PET) surface through surface-initiated reversible addition-fragmentation chain-transfer (SI-RAFT) polymerization. The tethered linear brushes on sheets were then thiolated with ethanolamine, followed by oxidation to form loop brushes.
View Article and Find Full Text PDFMetab Eng Commun
December 2024
Instituto de Tecnologia Química e Biológica António Xavier, Oeiras, Portugal.
Polyethylene Terephthalate (PET) is a petroleum-based plastic polymer that, by design, can last decades, if not hundreds of years, when released into the environment through plastic waste leakage. In the pursuit of sustainable solutions to plastic waste recycling and repurposing, the enzymatic depolymerization of PET has emerged as a promising green alternative. However, the metabolic potential of the resulting PET breakdown molecules, such as the two-carbon (C2) molecule ethylene glycol (EG), remains largely untapped.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
December 2024
Department of Cardiology, A J Institute of Medical Sciences and Research Centre, Mangaluru, India.
The ruptured sinus of Valsalva aneurysm (RSOV), a rare but well-recognized clinical entity, is invariably a form of left-to-right shunt due to rupture into right-sided chambers. It causes profound hemodynamic effects, especially when the rupture is acute. Like most other left-to-right shunts, it was only a matter of time before this rare defect also became amenable to transcatheter closure (TCC).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!