Telerobotic system concept for real-time soft-tissue imaging during radiotherapy beam delivery.

Med Phys

Department of Mechanical Engineering, Stanford University, Stanford, California 94305, USA.

Published: December 2010

Purpose: The curative potential of external beam radiation therapy is critically dependent on having the ability to accurately aim radiation beams at intended targets while avoiding surrounding healthy tissues. However, existing technologies are incapable of real-time, volumetric, soft-tissue imaging during radiation beam delivery, when accurate target tracking is most critical. The authors address this challenge in the development and evaluation of a novel, minimally interfering, telerobotic ultrasound (U.S.) imaging system that can be integrated with existing medical linear accelerators (LINACs) for therapy guidance.

Methods: A customized human-safe robotic manipulator was designed and built to control the pressure and pitch of an abdominal U.S. transducer while avoiding LINAC gantry collisions. A haptic device was integrated to remotely control the robotic manipulator motion and U.S. image acquisition outside the LINAC room. The ability of the system to continuously maintain high quality prostate images was evaluated in volunteers over extended time periods. Treatment feasibility was assessed by comparing a clinically deployed prostate treatment plan to an alternative plan in which beam directions were restricted to sectors that did not interfere with the transabdominal U.S. transducer. To demonstrate imaging capability concurrent with delivery, robot performance and U.S. target tracking in a phantom were tested with a 15 MV radiation beam active.

Results: Remote image acquisition and maintenance of image quality with the haptic interface was successfully demonstrated over 10 min periods in representative treatment setups of volunteers. Furthermore, the robot's ability to maintain a constant probe force and desired pitch angle was unaffected by the LINAC beam. For a representative prostate patient, the dose-volume histogram (DVH) for a plan with restricted sectors remained virtually identical to the DVH of a clinically deployed plan. With reduced margins, as would be enabled by real-time imaging, gross tumor volume coverage was identical while notable reductions of bladder and rectal volumes exposed to large doses were possible. The quality of U.S. images obtained during beam operation was not appreciably degraded by radiofrequency interference and 2D tracking of a phantom object in U.S. images obtained with the beam on/off yielded no significant differences.

Conclusions: Remotely controlled robotic U.S. imaging is feasible in the radiotherapy environment and for the first time may offer real-time volumetric soft-tissue guidance concurrent with radiotherapy delivery.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.3515457DOI Listing

Publication Analysis

Top Keywords

soft-tissue imaging
8
beam
8
beam delivery
8
real-time volumetric
8
volumetric soft-tissue
8
radiation beam
8
target tracking
8
robotic manipulator
8
image acquisition
8
clinically deployed
8

Similar Publications

The advancement of neural radiance fields (NeRFs) has facilitated the high-quality 3D reconstruction of complex scenes. However, for most NeRFs, reconstructing 3D tissues from endoscopy images poses significant challenges due to the occlusion of soft tissue regions by invalid pixels, deformations in soft tissue, and poor image quality, which severely limits their application in endoscopic scenarios. To address the above issues, we propose a novel framework to reconstruct high-fidelity soft tissue scenes from low-quality endoscopic images.

View Article and Find Full Text PDF

Spontaneous Chest Wall Hematoma in a Hemodialysis Patient: A Case Report.

J Clin Med

January 2025

Department of Plastic and Reconstructive Surgery, Chonnam National University Hospital, Chonnam National University Medical School, 42 Jebong-ro, Dong-gu, Gwangju 61469, Republic of Korea.

: Spontaneous chest wall hematomas are rare but potentially life-threatening complications, particularly in patients with multiple comorbidities such as those undergoing hemodialysis. This case report aims to highlight the significance of early diagnosis and appropriate management in preventing complications associated with this condition. : We report the case of a 79-year-old man with end-stage renal disease on hemodialysis, presenting with a large spontaneous hematoma (18.

View Article and Find Full Text PDF

: Combining autologous fat grafting with implant placement is meant to improve the quality of implant-based breast reconstruction. The present study explores the concept of multi-stage composite breast reconstruction with repeated sessions of autologous fat grafting to increase mastectomy flap thickness and provide better pre-pectoral implant coverage. : Twenty-five consecutive patients underwent bilateral multi-stage composite expander-to-implant breast reconstruction and reverse expansion from August 2020 to April 2024.

View Article and Find Full Text PDF

: Over the past decade, significant advances have been made in image-guided radiotherapy (RT) particularly with the introduction of magnetic resonance (MR)-guided radiotherapy (MRgRT). However, the optimal clinical applications of MRgRT are still evolving. The intent of this analysis was to describe our institutional MRgRT utilization patterns and evolution therein, specifically as an early adopter within a center endowed with multiple other technology platforms.

View Article and Find Full Text PDF

This review evaluates needle navigation technologies in minimally invasive cardiovascular surgery (MICS), identifying their strengths and limitations and the requirements for an ideal needle navigation system that features optimal guidance and easy adoption in clinical practice. A systematic search of PubMed, Web of Science, and IEEE databases up until June 2024 identified original studies on needle navigation in MICS. Eligible studies were those published within the past decade and that performed MICS requiring needle navigation technologies in adult patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!