A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the Bullard, GlideScope, Viewmax, and Macintosh laryngoscopes using a cadaver model to simulate the difficult airway. | LitMetric

Study Objective: To assess the performance and cervical (C)-spine movement associated with laryngoscopy using the Bullard laryngoscope (BL), GlideScope videolaryngoscope (GVL), Viewmax, and Macintosh laryngoscopes during conditions of a) unrestricted and b) restricted C-spine and temporomandibular joint (TMJ) mobility.

Design: Prospective, controlled, randomized, crossover study.

Setting: University teaching hospital.

Subjects: 21 cadavers with intact C-spine anatomy.

Interventions: Each cadaver underwent to total of 8 intubation attempts to complete the intubation protocol using all four devices under unrestricted and restricted C-spine and TMJ mobility.

Measurements: Laryngoscopic view was graded using the modified Cormack-Lehane system. Time to best laryngoscopic view and total time to intubation were recorded. C-spine movement was measured between McGregor's line and each vertebra from radiographs taken at baseline and at best laryngoscopic view.

Main Results: During both intubating conditions, the BL achieved the highest number of modified Cormack-Lehane grade 1 and 2A laryngoscopic views as compared to the other three devices (P < 0.05) and had fewer intubation failures than the Viewmax or Macintosh laryngoscopes (P < 0.05). The GVL had superior laryngoscopic performance as compared to the Viewmax and Macintosh laryngoscopes (P < 0.05) and had fewer intubation failures than those two devices (P < 0.05). All devices except the Macintosh laryngoscope in restricted mobility achieved median times to intubation in less than 30 seconds. For both conditions, BL showed the least total absolute movement between Occiput/C1 and C3/C4 of all the devices (all P < 0.05). Most of the difference was seen at C1/C2.

Conclusions: In cadavers with unrestricted and restricted C-spine mobility, the BL provided superior laryngoscopic views, comparable intubating times, and less C-spine movement than the GVL, Viewmax, or Macintosh laryngoscopes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jclinane.2010.06.008DOI Listing

Publication Analysis

Top Keywords

viewmax macintosh
20
macintosh laryngoscopes
20
c-spine movement
12
unrestricted restricted
12
restricted c-spine
12
devices 005
12
gvl viewmax
8
laryngoscopic view
8
modified cormack-lehane
8
best laryngoscopic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!