A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a biodegradable tissue adhesive based on functionalized 1,2-ethylene glycol bis(dilactic acid). II. | LitMetric

In body regions where damage and bleeding must be avoided, a substitute for mechanical tissue fixation by sutures or staplers is needed. Since tissue adhesives provide easy and fast handling they are a promising alternative. The present study reports the development and analysis of a tissue adhesive that consists of two adhesive components: hexamethylene diisocyanate (HDI) functionalized 1,2-ethylene glycol bis(dilactic acid) (ELA-NCO) and chitosan chloride. This composition was chosen based on preliminary studies on several chain elongation agents. The present study evaluates this adhesive system by IR-spectroscopy, tensile tests, and gel point measurements in comparison to fibrin glue. The system's in vitro biocompatibility was tested with mouse fibroblasts (L929) according to ISO 10993-5. Furthermore, an implantation study was performed in SPF-Wistar rats. The adhesive strength of manually applied mixtures or mixtures applied by double chamber syringes with a mixing extruder was determined to be significantly higher than that of fibrin glue on bovine muscle tissue at 37°C. Tensile strength increased further when exposure time of the adhesive was increased from 10 min to 48 h. The rheological gel point determination showed that the mixture of ELA-NCO/DMSO and chitosan chloride offers a time window large enough to readjust the fused joint during surgery, as opposed to fibrin glue. Additionally, the in vitro and in vivo biocompatibility studies of the adhesive system revealed no toxic effects on the surrounding tissue.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.31787DOI Listing

Publication Analysis

Top Keywords

fibrin glue
12
tissue adhesive
8
functionalized 12-ethylene
8
12-ethylene glycol
8
glycol bisdilactic
8
bisdilactic acid
8
chitosan chloride
8
adhesive system
8
gel point
8
adhesive
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!