A Ca(2+)-dependent TG activity, identified in the eye lens of several mammalian species, has long been implicated in cataract formation. The precise mechanism of the involvement of this enzyme in this process remains unclear. The purpose of this work was to investigate the modulatory effect of polyamines on TG activity during rabbit eye lens in vitro opacification. We observed, in an in vitro Ca(2+)-induced cataract model, a rapid decrease of the endogenous levels of SPD with the progression of opacification, paralleled by an increase of crystallin cross-linking by bis(γ-glutamyl)SPD. This pattern was reversed adding exogenous SPD to the incubation medium. Indeed, endogenous SPD levels were restored and cross-linking by bis(γ-glutamyl)SPD were drastically reduced. Surprisingly, under this experimental condition, the loss of transparency of lens was delayed. We found that exogenous SPD incubation led to a remarkable increase of mono(γ-glutamyl)SPD, likely responsible of the inhibition of cross-linking of lens crystallins and of the transparency persistence.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10930-011-9311-7DOI Listing

Publication Analysis

Top Keywords

eye lens
12
crystallin cross-linking
8
cross-linking bisγ-glutamylspd
8
exogenous spd
8
spd incubation
8
lens
5
spermidine delays
4
delays eye
4
lens opacification
4
opacification vitro
4

Similar Publications

Purpose: To assess the repeatability of lipid layer thickness (LLT) measurement using the LipiView® interferometer after daily disposable contact lens (CL) wear and correlation with ocular comfort in soft contact lens wearers.

Methods: A prospective study was conducted over two consecutive months, wherein CL wearers (n = 20) wore either Somofilcon A or Verofilcon A daily disposable CLs in a crossover design, switching lenses after 1 month. The pre-corneal tear film LLT was measured at the end of each month after CLs had been worn for at least 6 h.

View Article and Find Full Text PDF

Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study.

Ophthalmic Physiol Opt

January 2025

Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.

Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.

View Article and Find Full Text PDF

Comparison of two-year myopia control efficacy between spectacle lenses with highly aspherical lenslets and orthokeratology lenses.

Cont Lens Anterior Eye

January 2025

State Key Laboratory of Ophthalmology, Optometry and Vision Science, Eye Hospital, Wenzhou Medical University, Wenzhou, China; National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital Wenzhou Medical University, Wenzhou, China. Electronic address:

Purpose: To compare the two-year efficacy of spectacle lenses with highly aspherical lenslets (HAL) and orthokeratology (OK) lenses in managing myopia in children.

Methods: This retrospective study examined medical records from the Affiliated Eye Hospital of Wenzhou Medical University, involving 1683 HAL users and 1192 OK users. Participants were children aged 8-13 with a refractive error of -0.

View Article and Find Full Text PDF

A systematic review of the effectiveness of leaded glasses for ensuring safety among healthcare professionals in fluoroscopy.

J Med Imaging Radiat Sci

January 2025

Instituto Politécnico de Coimbra, ESTESC - Coimbra Health School, Medical Imaging and Radiotherapy, Rua 5 de Outubro, S. Martinho do Bispo, Coimbra 3046-854, Portugal. Electronic address:

Background: Currently, there is an increase in procedures across various clinical specialties involving the use of ionising radiation.

Objective: The primary objective of this systematic review is to analyse and compare the existing literature regarding the effectiveness of leaded glasses for healthcare professionals.

Methods: Comprehensive literature searches were conducted for relevant studies published between 2018 and 2023 using the Scopus, PubMed, and Web of Science databases according to preferred reporting items for systematic reviews and meta-analyses (PRISMA) methodology.

View Article and Find Full Text PDF

Ocular Injuries and Intimate Partner Violence: A Review of the Literature.

Clin Ophthalmol

January 2025

Retina Service, Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA.

Purpose Of Review: Intimate partner violence (IPV) is a leading cause of death and disability across the world. We sought to investigate the prevalence and clinical presentation of ocular injuries in IPV.

Recent Findings: Literature review revealed 16 published studies that evaluated ocular injuries in IPV, of which the study types included 9 retrospective studies, 2 prospective, 1 review, 1 invited commentary, 2 case reports, and 1 population-based cross-sectional survey.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!