A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Utility of ultrasonography for detection of gastric fluid during urgent endotracheal intubation. | LitMetric

Purpose: Aspiration of gastric contents is a dangerous complication of urgent endotracheal intubation (UEI). Left upper quadrant (LUQ) ultrasonography may have the potential to decrease this complication by identifying patients with gastric fluid content, thereby allowing the UEI team to evacuate gastric contents prior to intubation.

Methods: This was an observational study of 80 UEIs where LUQ ultrasonography was performed in a medical intensive care unit of a tertiary care hospital. The subjects were 80 patients requiring UEI. Gastric fluid content was identified as an anechoic or hypoechoic space in the appropriate anatomic position. If potentially consequential fluid was identified, it was evacuated using a gastric tube. Repeat LUQ ultrasonography confirmed removal of gastric contents prior to induction.

Results: A total of 80 patients had LUQ ultrasonography performed; 19 (24%) had gastric fluid content identified and 13 (16%) had sufficient gastric fluid content such that the UEI team proceeded with gastric tube insertion. Following gastric fluid removal, repeat ultrasonography showed absence of gastric fluid. Gastric fluid volume removed was 553 ± 290 ml (mean ± standard deviation, SD). None of the 80 patients had a clinically consequential aspiration event. Performance of ultrasonography took fewer than 2 min. No patient had complication related to the ultrasonography or removal of gastric contents.

Conclusions: Ultrasonography is useful for the detection of gastric fluid. This technique may have utility in reducing risk of a clinically consequential aspiration event during UEI.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00134-010-2125-9DOI Listing

Publication Analysis

Top Keywords

gastric fluid
36
luq ultrasonography
16
fluid content
16
gastric
15
gastric contents
12
fluid
10
ultrasonography detection
8
detection gastric
8
urgent endotracheal
8
endotracheal intubation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!