Background: A low heart rate (HR), associated with a prolonged slow filling phase (SF), is necessary to obtain a high quality coronary CT at a low radiation dose with conventional 64 multidetector-row computed tomography (MDCT). The purpose of our study was to confirm the safety of injecting propranolol (2-10 mg) into the vein for lowering heart rate in patients requiring MDCT and to document the effect of the drug on HR, PQ and SF.

Method: Of 1290 consecutive patients who were initially considered for enrollment in the coronary MDCT study, 40 patients with atrial fibrillations, 3 with atrial flutters, and 13 with artificial pacemakers were excluded. Of the remaining 1234 patients (M/F=714/520), 331 had already taken an oral beta-blocker before the CT examination, and were included in the study. In patients with no contraindications, propranolol was aggressively injected (2-10 mg) into the vein to reduce the HR.

Result: In patients not taking an oral beta blocker, 2 mg propranolol reduced the HR by -10±5 bpm and 10 mg, by -20±7 bpm. However, in patients taking an oral beta-blocker, the decrease in HR by propranolol was minimal (2 mg, -6±4 bpm; 10 mg, -10±6 bpm). Propranolol significantly prolonged the PQ interval (from 169±27 to 179±29 ms, P<0.0001), and SF (from 125±69 to 264±79 ms, P<0.0001). Adverse effects of propranolol injection were observed in only 3 [2 mild hypotension and 1 paroxysmal atrial fibrillation (recovered to sinus rhythm by DC counter shock)] of 3212 patients. All 3 patients became stable after 1 or 2 hours of rest and could return home.

Conclusion: Propranolol injection was a relatively safe and useful method to reduce HR and prolong SF, necessary for obtaining high quality coronary MDCT with a low radiation dose.

Download full-text PDF

Source
http://dx.doi.org/10.6009/jjrt.66.1539DOI Listing

Publication Analysis

Top Keywords

multidetector-row computed
8
heart rate
8
2-10 vein
8
study patients
8
oral beta-blocker
8
patients oral
8
patients
7
propranolol
6
[usefulness safety
4
safety propranolol
4

Similar Publications

Accuracy of the Hounsfield Unit Values Measured by Implant Planning Software.

Dent J (Basel)

December 2024

Department of Oral and Maxillofacial Implantology, Kanagawa Dental University, Yokosuka 238-8580, Japan.

: The measurement of Hounsfield units (HU) during implant treatment planning is important. Currently, various manufacturers' implant planning software programs offer HU capabilities; however, their accuracy remains unverified. In this study, we aimed to validate the accuracy of HU values measured by implant planning software programs.

View Article and Find Full Text PDF

Multidetector-row computed tomographic angiography (angio-CT) aims to achieve optimal opacification of the vascular compartment of interest. The distribution and quality of vascular opacification are influenced by patient-related factors, contrast medium (CM)-related factors, and scanner-related factors. This systematic review evaluates these factors and their effects on contrast enhancement.

View Article and Find Full Text PDF

Objective: This study aimed to investigate the relationship between clinical findings and the trabecular microstructure of the subchondral bone in patients with hip osteoarthritis (OA) due to developmental dysplasia of the hip (DDH) using multidetector row computed tomography (MDCT).

Design: A total of 63 patients (69 hips) with OA due to DDH were retrospectively reviewed, with 12 healthy controls being included for comparison. Clinical evaluation was performed using the Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ).

View Article and Find Full Text PDF

Objective:  This study aimed to investigate whether the calculated predicted value of the estimated glomerular filtration rate from serum creatinine levels (eGFRcreat-PV) from multiple regression equations using the anteroposterior diameter of the renal sinus (APDRS) measured on multidetector row computed tomography (MDCT) axial images and easily obtainable chronic kidney disease (CKD) risk factors (age and body mass index, BMI) is useful for separating CKD stages.

Material And Methods:  The Review Board approved this study, and the additional approval requirement was waived for this retrospective study. We investigated the association between eGFRcreat and age, BMI, and APDRS using stepwise multivariate regression analysis in 98 patients who underwent MDCT and calculated eGFRcreat-PV from the obtained multiple regression equation.

View Article and Find Full Text PDF

Cone beam computed tomography (CBCT) has potential advantages for developing portable, cost-effective point-of-care CT systems for intracranial imaging, such as early stroke diagnosis, hemorrhage detection, and intraoperative navigation. However, large volume imaging with flat panel detector based CBCT significantly increases the scattered radiation fluence which reduces its image quality and utility. To address these issues, a compact CBCT concept with enhanced image quality was investigated for intracranial imaging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!