Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2010.12.011DOI Listing

Publication Analysis

Top Keywords

"revision hip
4
hip arthroplasty
4
arthroplasty short
4
short femoral
4
femoral component
4
component fractured
4
fractured hydroxyapatite
4
hydroxyapatite fully
4
fully coated
4
coated femoral
4

Similar Publications

Purpose: To determine the patient demographics and incidence of hip arthroscopy after total hip arthroplasty using the PearlDiver database.

Methods: This is a retrospective study of patients undergoing total hip arthroplasty and arthroscopic hip surgery. The PearlDiver Claims Database was queried using Current Procedural Terminology (CPT) codes for records from 2010 to 2021.

View Article and Find Full Text PDF

Introduction: The outcomes of total hip arthroplasty (THA) are highly dependent upon the restoration of native hip biomechanics and optimal component positioning. Robotic technologies for THA have rapidly improved the accuracy of component positioning and maintaining the planned center of rotation. While robotic-assisted THA (RA-THA) has primarily been employed in surgically intricate cases, its potential benefits in scenarios of diminished surgical complexity remain less explored.

View Article and Find Full Text PDF

A Unique Cause of Chronic Right Hip Pain and Unilateral Leg Swelling 10 Years Following Total Hip Arthroplasty.

Am J Phys Med Rehabil

November 2024

Department of Physical Medicine & Rehabilitation, University of Minnesota, Minneapolis, Minnesota.

Patient is a 64-year-old female with a history of right total hip arthroplasty (THA) who presented with progressive painful right lower extremity edema and chronic groin pain for 2 years. A CT scan from October 2021 revealed an expanding, large iliopsoas bursal fluid collection that caused compression of the right common femoral artery and vein in June 2023. Further workup excluded deep venous thrombosis or infectious causes.

View Article and Find Full Text PDF

Introduction: The RM Pressfit vitamys is an uncemented, titanium particle-coated, isoelastic monoblock cup made of vitamin E blended highly cross-linked polyethylene. We addressed the following questions: (1) What are the clinical and (2) radiographic outcomes 10 years after implantation? (3) What is the revision rate?

Methods: In this prospective observational study in a tertiary care centre we investigated all consecutive cases of total hip replacement with the RM Pressfit vitamys cup between September 2009 and November 2011. It was implanted in 162 hips, 49.

View Article and Find Full Text PDF

: Vancomycin is commonly used in the treatment of periprosthetic joint infection (PJI), and trough concentrations are measured to ascertain that they are within the therapeutic range. It has not been investigated what proportion of vancomycin concentrations during treatment of PJI patients is accurately within this range, how many dose adjustments are commonly needed, and which patient factors predispose towards aberrations from the desired range. : In this single-center cohort study, we investigated vancomycin trough concentrations in 108 patients with surgically treated PJI who received IV administered vancomycin treatment post-operatively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!