Purpose: The present study aimed at investigating the influence of the level of dynamism of two different visual display terminal tasks on spontaneous eyeblink rate, blink amplitude, and tear film integrity.

Material And Methods: A total of 25 healthy, young volunteers participated in the study. Blink rate and blink amplitude were recorded in silent primary gaze conditions and while subjects were playing two computer games of similar cognitive demands but different rate of visual information presentation. For each experimental condition, tear volume was evaluated by measuring meniscus height and with the red phenol thread test. Fluorescein and non-invasive break-up time tests, as well as the observation of interference patterns and the estimation of the dry area extension, were employed to assess tear stability.

Results: Statistically significant differences were revealed in blink rate (F = 595.85, p < 0.001) and blink amplitude (χ(2) = 34.00, p < 0.001), with blink rate during fast- and slow-paced game play decreasing to almost 1/3 and 1/2 of baseline levels, respectively, and with a larger percentage of incomplete blinks during dynamic tasks. Fluorescein and non-invasive break-up time tests and dry area extension were able to differentiate between experimental conditions in general (F = 408.42, p < 0.001; F = 163.49, p < 0.001; χ(2) = 20.74, p < 0.001), as well as between fast- and slow-paced games, thus suggesting that tear quality was more affected than tear volume.

Conclusions: Blink rate, blink amplitude, and tear film stability were compromised during the most dynamic visual display terminal task, suggesting a negative influence of not only the cognitive aspects of the task, but also of the rate at which new visual information is presented. Frequent breaks and blinking awareness training are recommended for visual display terminal users requiring prolonged periods of visually demanding dynamic computer play or work.

Download full-text PDF

Source
http://dx.doi.org/10.3109/02713683.2010.544442DOI Listing

Publication Analysis

Top Keywords

blink rate
12
rate blink
12
blink amplitude
12
amplitude tear
8
tear film
8
visual display
8
display terminal
8
terminal tasks
8
blink
6
tear
4

Similar Publications

The present study introduces the idea of a novel fluorescence-based imaging technique combined with a microfluidic platform that enables a precise control of dark transient state populations of fluorescent probes flowing over a uniform, top flat supergaussian excitation field with a constant flow rate. To demonstrate the imaging capability of the proposed detection method, numerical simulations have been performed by considering laser, microscope and flow parameters of experimental setup together with photophysical model and electronic transition rates of fluorescent dyes. As an output data to be assessed, fluorescence image data is simulated numerically for bromine-free carboxyfluorescein and its brominated derivatives having different numbers of bromine atoms.

View Article and Find Full Text PDF

Tear film lipid layer thickness and blink dynamics in patients with blepharospasm.

BMC Ophthalmol

January 2025

Department of Ophthalmology, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.

Background: This study investigates the effect of botulinum toxin A on lipid layer thickness (LLT) and blink dynamics in patients with benign essential blepharospasm (BEB) compared to dry eye disease (DED) patients.

Methods: We reviewed the medical records of patients with dry eye disease (DED) and BEB treated with botulinum toxin A (BoT A) injections. Data on demographics, lipid layer thickness (LLT), meiboscore, and blink dynamics measured using a LipiView II interferometer before and 2 months after BoT A were collected.

View Article and Find Full Text PDF

Blink completeness and rate in dry eye disease: An investigator-masked, prospective registry-based, cross-sectional, prognostic study.

Cont Lens Anterior Eye

January 2025

Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand. Electronic address:

Purpose: To investigate the prognostic ability of blink rate and the proportion of incomplete blinking to predict dry eye disease diagnosis, as defined by the TFOS DEWS II criteria.

Methods: A total of 453 community residents (282 females, 171 males; mean ± SD age, 37 ± 19 years) were recruited in an investigator-masked, prospective registry-based, cross-sectional, prognostic study. Dry eye symptomology, tear film quality, and ocular surface characteristics were assessed in a single clinical session, and blink parameters evaluated by an independent masked observer.

View Article and Find Full Text PDF

A recruiting rate () of 0.1-5 s has been proposed as the criterion for super-resolution spontaneously blinking rhodamines. Accurate prediction of the recruiting rate () of rhodamines is very important for developing spontaneously blinking rhodamines.

View Article and Find Full Text PDF

Understanding the environment-dependent stability and photoluminescence (PL) properties of advanced perovskite materials remains a challenge with conflicting views. Herein, we investigated the influence of the host matrix (poly(methyl methacrylate) (PMMA) and polystyrene (PS)) and atmospheric conditions (ambient and N) on the PL properties of a CsPbBr perovskite quantum dot (PQD) using single-particle spectroscopy. Despite the same PL blinking mechanism, the PL properties of the PQD were considerably affected by the environmental conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!