A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intraoperative choroidal detachment during 23-gauge vitrectomy. | LitMetric

Intraoperative choroidal detachment during 23-gauge vitrectomy.

Retina

Vitreoretinal Service, Department of Ophthalmology and Visual Sciences, University of Iowa, Iowa City, Iowa, USA.

Published: May 2011

Purpose: To review intraoperative choroidal detachments during 23-gauge vitrectomy and examine possible mechanism(s) involved.

Methods: A retrospective consecutive case review of 23-gauge vitrectomies was performed. Main outcomes included choroidal detachment incidence, location, extent, relation to infusion cannula, and postoperative course. Laboratory study of human donor eyes was conducted by placing 23-gauge cannulas at various angles through the pars plana and injecting viscoelastic material after cannula retraction.

Results: Among 338 consecutive 23-gauge vitrectomy cases, 12 (3.55%) intraoperative choroidal detachments occurred. These included 6 (1.77%) serous detachments, 4 (1.18%) limited hemorrhagic detachments, and 1 case each of gas and silicone oil during an exchange. In four of six serous detachments and three of four hemorrhagic detachments, the detachment originated from the infusion cannula site. Intraoperative infusion cannula retraction (5 of 12 cases) and blockage (2 of 12 cases) caused transient hypotony. All cases of serous, hemorrhagic, and gas detachment resolved without intervention. Cannulas were placed at various angles to the sclera in human donor eyes. Choroidal detachments were produced after injecting viscoelastic material through obliquely placed cannulas after 1 mm of retraction.

Conclusion: Infusion cannula retraction is an important mechanism and risk factor for the development of intraoperative choroidal detachment during 23-gauge vitrectomy. Precautions to prevent retraction and intraoperative repositioning may help avoid this complication.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IAE.0b013e3181f4429bDOI Listing

Publication Analysis

Top Keywords

intraoperative choroidal
16
23-gauge vitrectomy
16
infusion cannula
16
choroidal detachment
12
choroidal detachments
12
detachment 23-gauge
8
human donor
8
donor eyes
8
cannulas angles
8
injecting viscoelastic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!