Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacc.2010.08.642DOI Listing

Publication Analysis

Top Keywords

corevalve transcatheter
4
transcatheter aortic
4
aortic valve
4
valve implantation
4
implantation subclavian
4
subclavian artery
4
artery comparison
4
comparison transfemoral
4
transfemoral approach
4
corevalve
1

Similar Publications

Transcatheter Edge-to-Edge Repair in Patients With Complex Tricuspid Valve Anatomy.

JACC Cardiovasc Interv

December 2024

University of Virginia, Charlottesville, Virginia, USA. Electronic address: https://twitter.com/psorajja.

Article Synopsis
  • Untreated severe tricuspid regurgitation (TR) is linked to poor health outcomes, making effective treatment essential.
  • The study evaluated the 1-year results of transcatheter edge-to-edge repair (TEER) using the TriClip system in patients with complex tricuspid valve issues, finding significant improvements in patient survival and quality of life.
  • Results showed that 81% of patients experienced a reduction in TR to moderate or less after one year, with no major adverse effects noted in the first 30 days post-procedure.
View Article and Find Full Text PDF

Recently, an increase in the number of patients with severe aortic stenosis eligible for transcatheter aortic valve implantation (TAVI) has been observed worldwide. In order to reduce waiting lists, provide to all patients referred to us equal access to care and to further improve the collaboration with spoke centers, we developed a specific Hub & Spoke specific protocol for TAVI. According to our protocol, a clinical selection (with echo and computed tomography scan) is done by Spoke centers, the case is discussed with a multidisciplinary team online and the procedure is planned (access, valve type size).

View Article and Find Full Text PDF
Article Synopsis
  • The study focuses on the impact of tricuspid regurgitation (TR) on heart remodeling, comparing outcomes in patients treated with the TriClip device versus those receiving standard medical therapy in a randomized controlled trial.
  • Researchers utilized advanced imaging techniques, including cardiac magnetic resonance and 4D-CT, to assess heart changes at baseline, 30 days, and one year follow-ups.
  • Results showed that the TriClip significantly reduced TR volume by 70% at 30 days, leading to notable reductions in right ventricular size and area, with these improvements maintained after one year, unlike the control group.
View Article and Find Full Text PDF

Redo-TAVI with the SAPIEN 3 valve in degenerated calcified CoreValve/Evolut explants.

EuroIntervention

November 2024

Cardiovascular Translational Lab, Centre for Heart Lung Innovation, University of British Columbia and Providence Health Care, St. Paul's Hospital, Vancouver, Canada.

Article Synopsis
  • Redo-transcatheter aortic valve implantation (TAVI) is often needed for failed aortic valves, specifically examining SAPIEN 3 (S3) valves in degenerated CoreValve/Evolut (CV/EV) valves, which is not fully understood.
  • The study assessed the performance of S3 valves following implantation in calcified CV/EV valves through various hydrodynamic tests, measuring factors like mean gradient, effective orifice area, and leaflet behaviors.
  • Results indicated that S3 valves generally performed well, showing decreased mean gradient and acceptable effective orifice area, but issues like underexpansion, leaflet pinwheeling, and calcium protrusion were noted, highlighting the need for further research on long
View Article and Find Full Text PDF

Thrombogenic Risk Assessment of Transcatheter Prosthetic Heart Valves Using a Fluid-Structure Interaction Approach.

Comput Methods Programs Biomed

December 2024

Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA. Electronic address:

Background And Objective: Prosthetic heart valve interventions such as TAVR have surged over the past decade, but the associated complication of long-term, life-threatening thrombotic events continues to undermine patient outcomes. Thus, improving thrombogenic risk analysis of TAVR devices is crucial. In vitro studies for thrombogenicity are typically difficult to perform.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!