Purpose: This investigation aimed to quantify the typical variation for kinetic and kinematic variables measured during loaded jump squats.
Methods: Thirteen professional athletes performed six maximal effort countermovement jumps on four occasions. Testing occurred over 2 d, twice per day (8 AM and 2 PM) separated by 7 d, with the same procedures replicated on each occasion. Jump height, peak power (PP), relative peak power (RPP), mean power (MP), peak velocity (PV), peak force (PF), mean force (MF), and peak rate of force development (RFD) measurements were obtained from a linear optical encoder attached to a 40 kg barbell.
Results: A diurnal variation in performance was observed with afternoon values displaying an average increase of 1.5-5.6% for PP, RPP, MP, PV, PF, and MF when compared with morning values (effect sizes ranging from 0.2-0.5). Day to day reliability was estimated by comparing the morning trials (AM reliability) and the afternoon trials (PM reliability). In both AM and PM conditions, all variables except RFD demonstrated coefficients of variations ranging between 0.8-6.2%. However, for a number of variables (RPP, MP, PV and height), AM reliability was substantially better than PM. PF and MF were the only variables to exhibit a coefficient of variation less than the smallest worthwhile change in both conditions.
Discussion: Results suggest that power output and associated variables exhibit a diurnal rhythm, with improved performance in the afternoon. Morning testing may be preferable when practitioners are seeking to conduct regular monitoring of an athlete's performance due to smaller variability.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1123/ijspp.5.4.546 | DOI Listing |
J Environ Radioact
January 2025
Hama Agricultural Regeneration Research Centre, Fukushima Agricultural Technology Center, Minami-soma, Fukushima, 975-0036, Japan.
Radioactive cesium released into the atmosphere caused by the Fukushima Dai-ichi Nuclear Power Plant accident in March 2011 has contaminated the surrounding area. We confirmed the applicability of in-situ methods to evaluate the depth distribution of Cs by employing the ratio of Compton-scattering and photo-peak components (r) obtained from measured gamma-ray spectra. In the present study, we applied the in-situ method to farmlands in Fukushima Prefecture whose sites were disturbed by decontamination and plowing operations.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
College of Architecture and Civil Engineering, Beijing University of Technology, Beijing 100124, China.
ISA Trans
January 2025
School of Control and Computer Engineering, North China Electric Power University, Beijing 102206, China.
Improving the flexible and deep peak shaving capability of supercritical (SC) unit under full operating conditions to adapt a larger-scale renewable energy integrated into the power grid is the main choice of novel power system. However, it is particularly challenging to establish an accurate SC unit model under large-scale variable loads and deep peak shaving. To this end, a data-driven modeling strategy combining Transformer-Extra Long (Transformer-XL) and quantum chaotic nutcracker optimization algorithm is proposed.
View Article and Find Full Text PDFJ Psychiatr Res
January 2025
Department of Psychiatry, Psychotherapy and Psychosomatics, University Hospital of Psychiatry, Zürich, Lenggstrasse 31, P.O. Box 363, 8032, Zürich, Switzerland.
Repetitive transcranial magnetic stimulation (rTMS) is an established psychiatric procedure for patients suffering from treatment-resistant depression (TRD). Biomarker identification to predict rTMS outcomes may assist the clinician in optimizing treatment selection. In recent years, different electrophysiological markers, in particular electroencephalographic (EEG) markers, were shown to yield discriminative power between responders and non-responders to various TRD treatments.
View Article and Find Full Text PDFSci Adv
January 2025
Department of Chemical Engineering, Kansas State University, Manhattan, KS, USA.
Protonic ceramic electrochemical cells (PCECs) can operate at intermediate temperatures (450° to 600°C) for power generation and hydrogen production. However, the operating temperature is still too high to revolutionize ceramic electrochemical cell technology. Lowering the operating temperature to <450°C will enable a wider material choice and reduce system costs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!