Optimal acquisition scheme for subwavelength localization microscopy of bleachable fluorophores.

Opt Lett

Mathematics and Statistics Department, California State Polytechnic University, 3801 West Temple Avenue, Pomona, California 91768, USA.

Published: January 2011

We consider the problem of optimizing superresolution microscopy with photoswitchable molecules that irreversibly photobleach. Using variational methods, we show that the number of single-molecule images is maximized in a simple scheme with a constant number of activated fluorophores per cycle. For high-speed acquisition, deviations from the optimal scheme do reduce the information collected but fortuitously also reduce certain types of errors, making the scheme very robust. Finally, we calculate the amount of information lost due to bleaching and noise.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.36.000289DOI Listing

Publication Analysis

Top Keywords

optimal acquisition
4
scheme
4
acquisition scheme
4
scheme subwavelength
4
subwavelength localization
4
localization microscopy
4
microscopy bleachable
4
bleachable fluorophores
4
fluorophores consider
4
consider problem
4

Similar Publications

In human-computer interaction, gesture recognition based on physiological signals offers advantages such as a more natural and fast interaction mode and less constrained by the environment than visual-based. Surface electromyography-based gesture recognition has significantly progressed. However, since individuals have physical differences, researchers must collect data multiple times from each user to train the deep learning model.

View Article and Find Full Text PDF

Quantitative and Visual Benefits of Data-Driven Motion Correction on Oncologic PET/CT: A Prospective Cross-sectional Study.

Acad Radiol

January 2025

Department of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, St. Louis, MO 63110 (S.I., M.A.T., M.I., C.S., R.L., A.H., R.L.W., T.J.F.). Electronic address:

Rationale And Objective: Conventional positron emission tomography (PET) respiratory gating utilizes a fraction of acquired PET counts (i.e., optimal gate [OG]), whereas elastic motion correction with deblurring (EMCD) utilizes all PET counts to reconstruct motion-corrected images without increasing image noise.

View Article and Find Full Text PDF

Motor variability regulation analysis in trampolinists.

J Biomech

January 2025

Laboratoire de Simulation et Modélisation du Mouvement, Université de Montréal, Montréal, QC, Canada. Electronic address:

In trampolining, optimizing body orientation during landing reduces injury risk and enhances performance. As trampolinists are subject to motor variability, anticipatory inflight corrections are necessary to regulate their body orientation before landing. We investigated the evolution of a) body orientation and b) limb position (i.

View Article and Find Full Text PDF

Phosphorus Fertilization and Chemical Root Pruning: Effects on Root Traits During the Nursery Stage in Two Mediterranean Species from Central Chile.

Plants (Basel)

January 2025

Escuela de Ingeniería en Agronomía, Campus Tecnológico Local San Carlos, Tecnológico de Costa Rica, Alajuela 22321001, Costa Rica.

The role of a plant root system in resource acquisition is relevant to confront drought events caused by climate change. Accordingly, nursery practices like phosphorous (P) fertilization and root pruning have been shown to modify root architecture; however, their combined benefits require further investigation in Mediterranean species. We evaluated the effect of applied P concentrations (0, 15, 60, and 120 mg L P) with or without chemical (copper) root pruning (WCu, WoCu, respectively) in and on morpho-physiological and root architecture traits.

View Article and Find Full Text PDF

To improve the performance of Radio Frequency Identification (RFID) multi-label systems, the multi-label network structure needs to be quickly located and optimized. A multi-label location measurement method based on the NLM-Harris algorithm is proposed in this paper. Firstly, multi-label geometric distribution images are obtained through a label image acquisition system of a multi-label semi-physical simulation platform with two vertical Charge-Coupled Device (CCD) cameras, and Gaussian noise is added to the image to simulate thermoelectric interference.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!