Sensitivity and amplitude calibration of a Fourier transform 3D quadrupole ion trap mass spectrometer.

J Mass Spectrom

Université de Provence, Laboratoire Chimie Provence-UMR CNRS 6264, Equipe Instrumentation et Réactivité Atmosphérique, Centre de Saint Jérôme Avenue Escadrille-Normandie-Niemen, 13397 Marseille, Cedex 20, France.

Published: February 2011

With a three-dimensional (3D) quadrupole ion trap running in a Fourier transform operating mode, the detected signal is an image of the collective motion of the confined ions. Consequently, it is assumed that the image signal is the sum of the axial trajectories of the simultaneously confined ions. The resulting frequency spectrum after Fourier transformation comprises frequency peaks at the axial secular frequencies of the confined species according to their mass/charge ratio. With a singly confined species, the maximal amplitude of the image signal is proportional to the amplitude of the secular axial frequency peak. The matrix method is employed to express the axial trajectory sampled at the confinement field period. In that case, the expression of the image signal, as well as its maximal amplitude, is calculated as a function of the trap operating conditions and initial axial positions and axial velocities of the ions. The initial position and velocity distributions are connected to the injection mode. With the steady ion flow injection mode (SIFIM) and an initial phase of the confinement field equal to kπ, the maximal amplitude of the image signal is proportional to either the sum of the initial axial positions or the number of confined ions and the mean value of the initial axial positions. By simulation, amplitude fluctuation of the frequency peak is then calculated for a number of ions ranging between some tens to some thousands of ions injected by SIFIM. The peak amplitude fluctuations induced by the fluctuations of the number of ions are seven times greater than those induced by the fluctuations of the distribution of the initial axial positions.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jms.1881DOI Listing

Publication Analysis

Top Keywords

image signal
16
initial axial
16
axial positions
16
confined ions
12
maximal amplitude
12
axial
9
fourier transform
8
quadrupole ion
8
ion trap
8
confined species
8

Similar Publications

Background: In neuroscience, Ca imaging is a prevalent technique used to infer neuronal electrical activity, often relying on optical signals recorded at low sampling rates (3 to 30 Hz) across multiple neurons simultaneously. This study investigated whether increasing the sampling rate preserves critical information that may be missed at slower acquisition speeds.

Methods: Primary neuronal cultures were prepared from the cortex of newborn pups.

View Article and Find Full Text PDF

The complicated neurological syndrome known as multiple sclerosis (MS) is typified by demyelination, inflammation, and neurodegeneration in the central nervous system (CNS). Managing this crippling illness requires an understanding of the complex interactions between neurophysiological systems, diagnostic techniques, and therapeutic methods. A complex series of processes, including immunological dysregulation, inflammation, and neurodegeneration, are involved in the pathogenesis of MS.

View Article and Find Full Text PDF

Retroviral genome selection and virion assembly remain promising targets for novel therapeutic intervention. Recent studies have demonstrated that the Gag proteins of Rous sarcoma virus (RSV) and human immunodeficiency virus type-1 (HIV-1) undergo nuclear trafficking, colocalize with nascent genomic viral RNA (gRNA) at transcription sites, may interact with host transcription factors, and display biophysical properties characteristic of biomolecular condensates. In the present work, we utilized a controlled in vitro condensate assay and advanced imaging approaches to investigate the effects of interactions between RSV Gag condensates and viral and nonviral RNAs on condensate abundance and organization.

View Article and Find Full Text PDF

Low-Complexity Timing Correction Methods for Heart Rate Estimation Using Remote Photoplethysmography.

Sensors (Basel)

January 2025

Department of Biomedical and Robotics Engineering, Incheon National University, Incheon 22012, Republic of Korea.

With the rise of modern healthcare monitoring, heart rate (HR) estimation using remote photoplethysmography (rPPG) has gained attention for its non-contact, continuous tracking capabilities. However, most HR estimation methods rely on stable, fixed sampling intervals, while practical image capture often involves irregular frame rates and missing data, leading to inaccuracies in HR measurements. This study addresses these issues by introducing low-complexity timing correction methods, including linear, cubic, and filter interpolation, to improve HR estimation from rPPG signals under conditions of irregular sampling and data loss.

View Article and Find Full Text PDF

For change detection in synthetic aperture radar (SAR) imagery, amplitude change detection (ACD) and coherent change detection (CCD) are widely employed. However, time-series SAR data often contain noise and variability introduced by system and environmental factors, requiring mitigation. Additionally, the stability of SAR signals is preserved when calibration accounts for temporal and environmental variations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!