Optimization and in vitro toxicity evaluation of G4 PAMAM dendrimer-risperidone complexes.

Eur J Med Chem

Laboratorio de Biomembranas, Departamento de Ciencia y Tecnología, Universidad Nacional de Quilmes, Roque Saenz Peña 352, Bernal, B1876BXD Buenos Aires, Argentina.

Published: March 2011

Risperidone is an approved antipsychotic drug belonging to the chemical class of benzisoxazole. This drug has low solubility in aqueous medium and poor bioavailability due to extensive first-pass metabolism and high protein binding (>90%). As new strategies to improve treatments efficiency are needed, we have studied cationic G4 PAMAM dendrimers' performance to act as efficient nanocarriers for this therapeutic drug. In this respect, we explored dendrimer-risperidone complexation dependence on solvent, temperature, pH and salt concentration, as well as in vitro cytotoxicity measured on L929 cell line and human red blood cells. The best dendrimer-risperidone incorporation was achieved when a mixture of 70:30 and 90:10 v/v chloroform:methanol was used, obtaining 17 and 32 risperidone molecules per dendrimer, respectively. No cytotoxicity on L929 cells was found when dendrimer concentration was below 3 × 10(-2) μM and risperidone concentration below 5.1 μM. Also, no significant hemolysis or morphological changes were observed on human red blood cells. Finally, attempting to obtain an efficient drug delivery system for risperidone, incorporation in G4 PAMAM dendrimers was optimized, improving drug solubility with low cytotoxicity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmech.2010.12.021DOI Listing

Publication Analysis

Top Keywords

human red
8
red blood
8
blood cells
8
drug
5
optimization vitro
4
vitro toxicity
4
toxicity evaluation
4
evaluation pamam
4
pamam dendrimer-risperidone
4
dendrimer-risperidone complexes
4

Similar Publications

Objective: Wound management can be costly and challenging to the health services' scarce resources. Information regarding the number of wounds in a community care setting and their associated aetiology will provide nurses and nurse managers with an insight into the specific needs of these clients with wounds and highlight areas where care or services can be improved or further developed. This research aimed to establish the prevalence and aetiology of wounds, the current delivery of wound care, wound documentation and referral pathways in an Irish community care setting.

View Article and Find Full Text PDF

Objective: Many people with inflammatory bowel disease (IBD) experience fatigue, pain and faecal incontinence that some feel are inadequately addressed. It is unknown how many have potentially reversible medical issues underlying these symptoms.

Methods: We conducted a study testing the feasibility of a patient-reported symptom checklist and nurse-administered management algorithm ('Optimise') to manage common medical causes of IBD-related fatigue, pain and faecal incontinence.

View Article and Find Full Text PDF

Evaluation of Cartilage-Like Matrix Formation in a Nucleus Pulposus-Derived Cartilage Analog Scaffold.

J Biomed Mater Res B Appl Biomater

January 2025

The Laboratory of Orthopaedic Tissue Regeneration & Orthobiologics, Department of Bioengineering, Clemson University, Clemson, South Carolina, USA.

The formation of fibrocartilage in microfracture (MFX) severely limits its long-term outlook. There is consensus in the scientific community that the placement of an appropriate scaffold in the MFX defect site can promote hyaline cartilage formation and improve therapeutic benefit. Accordingly, in this work, a novel natural biomaterial-the cartilage analog (CA)-which met criteria favorable for chondrogenesis, was evaluated in vitro to determine its candidacy as a potential MFX scaffold.

View Article and Find Full Text PDF

Photoplethysmography is a widely used optical technique to extract physiological information non-invasively. Despite its large use and adoption, multiple factors influence the signal shape and quality, including the instrumentation used. This work analyzes the variability of the DC component of the PPG signal at three source-detector distances (6 mm, 9 mm, and 12 mm) using green, red, and infrared light and four photodiodes per distance.

View Article and Find Full Text PDF

: Implementing self-sampling (SS) in cervical cancer screening requires comparable results to clinician-collected samples (CCS). Agreement measures are essential for evaluating HPV test performance. Previous studies on non-paired samples have reported higher viral cycle threshold (Ct) values in SS compared to CCS, affecting sensitivity for detecting cervical intraepithelial neoplasia grade 2 or worse (CIN2+).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!