Background: Steerable sheath technology is designed to facilitate catheter access, stability, and tissue contact in target sites of atrial fibrillation (AF) catheter ablation. We hypothesized that rhythm control after interventional AF treatment is more successful using a steerable as compared with a nonsteerable sheath access.

Methods And Results: One hundred thirty patients with paroxysmal or persistent drug-refractory AF undergoing their first ablation procedure were prospectively included in a randomized fashion in 2 centers. Ablation was performed by 10 operators with different levels of clinical experience. Treatment outcome was measured with serial 7-day Holter ECGs and additional symptom-based arrhythmia documentation. Single procedure success (freedom from AF and/or atrial macroreentrant tachycardia) was significantly higher in patients ablated with a steerable sheath (78% versus 55% after 3 months, P=0.005; 76% versus 53% after 6 months, P=0.008). Rate of pulmonary vein isolation, procedure duration, and radiofrequency application time did not differ significantly, whereas fluoroscopy time was lower in the steerable sheath group (33±14 minutes versus 45±17 minutes, P<0.001). Complication rates showed no significant difference (3.2% versus 5%, P=0.608). On multivariable analysis, steerable sheath usage remained the only powerful predictor for rhythm outcome after 6 months of follow-up (hazard ratio, 2.837 [1.197 to 6.723]).

Conclusions: AF catheter ablation using a manually controlled, steerable sheath for catheter navigation resulted in a significantly higher clinical success rate, with comparable complication rates and with a reduction in periprocedural fluoroscopy time.

Clinical Trial Registration: URL: http://clinicaltrials.gov. Unique identifier: NCT00469638.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCEP.110.957761DOI Listing

Publication Analysis

Top Keywords

steerable sheath
12
nonsteerable sheath
8
sheath technology
8
atrial fibrillation
8
steerable
5
sheath
5
steerable versus
4
versus nonsteerable
4
technology atrial
4
ablation
4

Similar Publications

Introduction: A leadless pacemaker (LLPM) was recommended for a patient with intermittent complete heart block and near-syncope.

Methods And Results: Delivery of LLPM is through a large sheath that has limited deflection and steerability. This report describes the successful deployment of a ventricular LLPM in a patient with prior surgical correction of AV septal defect with subsequent significant right atrial enlargement.

View Article and Find Full Text PDF

The integration of self-expandable nitinol frames with cable-driven parallel mechanisms offers a promising advancement in minimally invasive cardiovascular interventions. This study presents the design, fabrication, and verification of a miniaturized self-expandable nitinol frame to enhance catheter tip steerability and navigation within complex vascular anatomies. The frame is reduced in size for delivery through 7-8 Fr sheaths while accommodating diverse vascular diameters, allowing up to a maximum expansion of 15 mm.

View Article and Find Full Text PDF

Background: The new Amplatzer Steerable Delivery Sheath is a delivery system designed to improve ease-of-use and procedural results of left atrial appendage closure (LAAC). We aimed to compare procedural results after switching our LAAC program at a tertiary care center with the Amulet device to the Steerable Delivery Sheath, with a control group of LAAC employing the standard sheath.

Methods: The first n = 32 consecutively treated patients at our site using the Amulet device with the Steerable Delivery Sheath were included in this retrospective analysis.

View Article and Find Full Text PDF

Antegrade Fenestration During Thoracic Endovascular Aortic Repair for Preserving Isolated Left Vertebral Artery.

EJVES Vasc Forum

October 2024

Department of Vascular Surgery, The First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China.

Article Synopsis
  • An isolated left vertebral artery (ILVA) is often affected by aortic arch pathologies, and preserving its blood flow during endovascular repair can be challenging, with no clear consensus on the best strategy.
  • This case report details a successful endovascular procedure in a 72-year-old man with an ILVA, where a novel technique called antegrade needle-assisted fenestration was used to revascularize the artery without traditional surgical methods.
  • The patient had a favorable outcome, with follow-up imaging showing a patent ILVA and good aortic remodeling, suggesting this technique could be a valuable option for similar cases.
View Article and Find Full Text PDF
Article Synopsis
  • - The study examines the safety and efficacy of a new 8F variable loop multielectrode catheter for pulsed field ablation (PFA) in patients with atrial fibrillation, which simplifies catheter use compared to earlier complex designs.
  • - Out of 30 patients, all achieved complete pulmonary vein and posterior wall isolation, with an average procedural time of about 113 minutes and minimal complications, including a few transient cerebral lesions.
  • - The research highlights that this new catheter system provides effective PFA while maintaining a safety profile similar to existing options, showing promise for future use in treating atrial fibrillation.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!