A nuclear bomb particle containing 1.6 ng of Pu was investigated nondestructively with a position-sensitive α detector and a broad-energy HPGe γ-ray detector. An event-mode data acquisition system was used to record the data. α-γ coincidence counting was shown to be well suited to nondestructive isotope ratio determination. Because of the very small background, the 51.6 keV γ rays of (239)Pu and the 45.2 keV γ rays of (240)Pu were identified, which enabled isotopic ratio calculations. In the present work, the (239)Pu/((239)Pu+(240)Pu) atom ratio was determined to be 0.950 ± 0.010. The uncertainties were much smaller than in the previous more conventional nondestructive studies on this particle. Obtained results are also in good agreement with the data from the destructive mass spectrometric studies obtained previously by other investigators.

Download full-text PDF

Source
http://dx.doi.org/10.1021/es1033734DOI Listing

Publication Analysis

Top Keywords

nuclear bomb
8
bomb particle
8
α-γ coincidence
8
kev rays
8
determination 235u
4
235u 239pu
4
239pu 240pu
4
240pu 241am
4
241am nuclear
4
particle position-sensitive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?