Objectives: To evaluate the validity of using lateral intraoperative fluoroscopic imaging to assess the reduction of the tibial plafond articular surface, two hypotheses were tested: 1) the distal tibial subchondral shadow on the lateral ankle radiograph is created equally by the medial, central, and lateral portions of the distal tibia; and (2) displacement of a 5-mm width osteochondral fragment is consistently recognizable on lateral fluoroscopic imaging.
Methods: Six human fresh-frozen tibial plafond cadaveric specimens were sagitally sectioned in 5-mm increments after removal of the anterior soft tissue and stabilization of the position of the ankle through external fixation. To test the first hypothesis, a perfect lateral radiograph was taken after sectioning the specimens. The sagittal sections were then removed sequentially from medial to lateral. A perfect lateral radiograph was taken after each change. The sagittal sections were then removed beginning laterally and moving medially. A perfect lateral radiograph was taken after each change. The images were then compared with specific evaluation of the change in the subchondral shadow density. To test the second hypothesis, three malreductions were created by displacing a 5-mm osteochondral segment. After each malreduction, a perfect lateral radiograph was saved. These saved fluoroscopic images were placed in random order with lateral images of normal specimens. Four experienced ankle surgeons were then asked to determine whether the radiographs revealed displacement. Inter- and intraobserver reliability was then evaluated.
Results: First, the subchondral shadow of the distal tibia appears to be created by an equal confluence of the subchondral bone of the medial, central, and lateral aspects of the tibial plafond. Second, fellowship-trained observers experienced in pilon fracture treatment correctly identified malreduction only 45% of the time. Intraclass correlation coefficient revealed very poor interobserver reliability with an alpha reliability statistic of 0.183. Intraobserver reliability across all four observers yielded an alpha statistic of 0.474, indicating inconsistencies in observers' evaluation of identical images at separate viewings.
Conclusions: It is difficult to discern rotational or translational displacement of a 5-mm osteochondral fragment on a perfect lateral fluoroscopic view of the ankle. Even with what appears to be a perfect lateral fluoroscopic view intraoperatively, displacement may still be present. When small osteochondral fragments are present, direct visualization of the articular surface is necessary to confidently establish that an anatomic reduction has been achieved.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BOT.0b013e3181e52ec5 | DOI Listing |
Parasit Vectors
January 2025
Aggeu Magalhães Institute, Oswaldo Cruz Foundation (Fiocruz), Recife, Brazil.
Background: We standardized two recombinase polymerase amplification (RPA) assays coupled with lateral flow (LF) strips for the detection of Leishmania braziliensis and Leishmania infantum kinetoplast DNA (kDNA).
Methods: The RPA-LF assays were tested at different temperatures and reaction times, using DNA from cultured L. braziliensis and L.
Am J Pathol
December 2024
Department of Physiology and Biophysics, Center for Neurodegeneration and Regeneration, Zilkha Neurogenetic Institute, Keck School of Medicine, University of Southern California, Los Angeles, California; Neuromedicine PhD Program, Programs in Biomedical and Biological Sciences (PIBBS), Keck School of Medicine, University of Southern California, Los Angeles, California; Neuroscience Graduate Program, University of Southern California, Los Angeles, California. Electronic address:
EJNMMI Phys
December 2024
Department of Nuclear Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Center for Rare Diseases Research, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, 1# Shuaifuyuan, Dongcheng District, Beijing, 100730, China.
Background: There is a need for faster amyloid PET scans to reduce patients' discomfort, minimize movement artifacts, and increase throughput. The recently introduced uMI Panorama PET/CT system featuring enhanced spatial resolution and sub-200ps TOF offers the potential for shorter scan duration without sacrificing image quality or efficacy to detect Aβ deposition. The study aims to establish a faster acquisition protocol for [F]florbetapir PET imaging using digital PET/CT scanner uMI Panorama, while ensuring adequate image quality and amyloid-β (Aβ) detectability comparable to the standard 10-minute scan.
View Article and Find Full Text PDFWe treat edge-mode resonance that may exist at boundaries of transversely finite beams illuminating a photonic lattice. The lattice is in the dark state signifying a perfect bound state in the continuum (BIC). The dark state is non-radiative in symmetric systems because lateral waves cannot couple to the lattice due to destructive interference between counter-propagating waves.
View Article and Find Full Text PDFFacts Views Vis Obgyn
December 2024
Background: Several endometriosis classification systems have been proposed and published but the search for a universal language that communicates the complexity, laterality and severity of this disease continues. The authors introduce the Visual-Numeric Endometriosis Scoring System. VNESS is a novel system for describing surgical findings in each compartment of the pelvis in a way that is simple to use, visually intuitive and mirrors a laparoscopic image of the pelvis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!