Population and high-risk group screening for glaucoma: the Los Angeles Latino Eye Study.

Invest Ophthalmol Vis Sci

Doheny Eye Institute and the Department of Ophthalmology, University of Southern California, Los Angeles, California 90033, USA.

Published: August 2011

Purpose: To evaluate the ability of various screening tests, both individually and in combination, to detect glaucoma in the general Latino population and high-risk subgroups.

Methods: The Los Angeles Latino Eye Study is a population-based study of eye disease in Latinos 40 years of age and older. Participants (n = 6082) underwent Humphrey visual field testing (HVF), frequency doubling technology (FDT) perimetry, measurement of intraocular pressure (IOP) and central corneal thickness (CCT), and independent assessment of optic nerve vertical cup disc (C/D) ratio. Screening parameters were evaluated for three definitions of glaucoma based on optic disc, visual field, and a combination of both. Analyses were also conducted for high-risk subgroups (family history of glaucoma, diabetes mellitus, and age ≥65 years). Sensitivity, specificity, and receiver operating characteristic curves were calculated for those continuous parameters independently associated with glaucoma. Classification and regression tree (CART) analysis was used to develop a multivariate algorithm for glaucoma screening.

Results: Preset cutoffs for screening parameters yielded a generally poor balance of sensitivity and specificity (sensitivity/specificity for IOP ≥21 mm Hg and C/D ≥0.8 was 0.24/0.97 and 0.60/0.98, respectively). Assessment of high-risk subgroups did not improve the sensitivity/specificity of individual screening parameters. A CART analysis using multiple screening parameters-C/D, HVF, and IOP-substantially improved the balance of sensitivity and specificity (sensitivity/specificity 0.92/0.92).

Conclusions: No single screening parameter is useful for glaucoma screening. However, a combination of vertical C/D ratio, HVF, and IOP provides the best balance of sensitivity/specificity and is likely to provide the highest yield in glaucoma screening programs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3175989PMC
http://dx.doi.org/10.1167/iovs.09-5126DOI Listing

Publication Analysis

Top Keywords

screening parameters
12
sensitivity specificity
12
screening
9
population high-risk
8
glaucoma
8
los angeles
8
angeles latino
8
latino eye
8
eye study
8
visual field
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!