Background: Doppler-derived hemodynamic data for normal tricuspid mechanical valve prostheses are limited.
Methods: A comprehensive retrospective Doppler echocardiographic assessment of 78 normal St. Jude Medical Standard (St. Jude Medical, Inc., St. Paul, MN), CarboMedics Standard (CarboMedics, Inc., Sorin Group, Burnaby, British Columbia, Canada), and Starr-Edwards (Edwards Lifesciences, LLC, Irvine, CA) mechanical tricuspid valve prostheses was performed early after implantation. We used all the important Doppler-derived hemodynamic variables reported to date, including peak early diastolic velocity (E velocity), mean gradient, pressure half-time, time velocity integral of the tricuspid valve prosthesis (TVI(TVP)), and ratio of the time velocity integral of the tricuspid valve prosthesis to the time velocity integral of the left ventricular outflow tract (TVI(TVP)/TVI(LVOT)).
Results: The mean values obtained for the Doppler parameters did not differ significantly when the measurements from five or nine consecutive cardiac cycles were averaged. Pressure half-time was <130 msec in all 43 patients with St. Jude Medical Standard and CardioMedics Standard prostheses in whom it could be measured. Mean gradient <6 mm Hg, E velocity <1.9 m/s, TVI(TVP) <46 cm, and TVI(TVP)/TVI(LVOT) <2.1 were recorded in 59 (87%) of the 68 patients with either of these prostheses. Hemodynamic variables were considerably less favorable in patients with Starr-Edwards prostheses.
Conclusion: These calculated threshold values (mean + 2 SD) are useful for identifying normal tricuspid mechanical valve function. Prostheses with values for hemodynamic variables that are outside the mean + 2 SD parameters that we have calculated are most likely to be dysfunctional. However, in rare cases, mechanical tricuspid valve prostheses may be dysfunctional even when their hemodynamic parameters are within these specified ranges because of small body surface area or other factors.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.echo.2010.12.021 | DOI Listing |
J Clin Med
January 2025
Department of Cardiovascular Surgery, Ankara Yıldırım Beyazıt University Faculty of Medicine, 06010 Ankara, Türkiye.
Stuck prosthetic valves, often resulting from pannus formation or thrombus accumulation, represent a critical complication in prosthetic valve management, carrying significant risks for morbidity and mortality. This study aims to identify factors associated with stuck valve development and assess the effectiveness of interventions in restoring normal valve function. A total of 27 patients with stuck valves were analyzed, including mitral, aortic, and tricuspid valve cases.
View Article and Find Full Text PDFInt J Mol Sci
January 2025
Research Direction, Instituto Nacional de Cardiología Ignacio Chávez, Juan Badiano No. 1, Col. Sección XVI, Mexico City 14080, Mexico.
Deregulation of micro-RNAs (miRNAs) may contribute to mechanisms of injury in the bicuspid aortic valve (BAV). Our objective was to investigate the expression of miRNAs in aortic tissue from patients who underwent aortic valve replacement for aortic stenosis and its relationship with aortic dilatation. The study included 78 patients, 40 with bicuspid aortic valve (BAV) and 38 with tricuspid aortic valve (TAV).
View Article and Find Full Text PDFAm J Cardiol
January 2025
Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA. Electronic address:
This study sought to explore the clinical factors associated with classical low-flow low-gradient (C-LFLG) and normal-flow low-gradient (NFLG) aortic stenosis (AS) compared to high-gradient (HG) AS. We also compared clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR) across flow-gradient patterns. Patients with C-LFLG AS have a higher mortality rate after TAVR than those with HG AS.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
January 2025
TriHealth Heart & Vascular Institute, Cincinnati, Ohio, USA.
Introduction: A leadless pacemaker (LLPM) was recommended for a patient with intermittent complete heart block and near-syncope.
Methods And Results: Delivery of LLPM is through a large sheath that has limited deflection and steerability. This report describes the successful deployment of a ventricular LLPM in a patient with prior surgical correction of AV septal defect with subsequent significant right atrial enlargement.
Innovations (Phila)
January 2025
Division of Cardiothoracic Surgery, Emory University School of Medicine, Atlanta, GA, USA.
Objective: Percutaneous vegetation debulking has been reported to treat tricuspid valve infective endocarditis (TVIE), but data on feasibility compared with conventional surgical strategies are limited. We aimed to compare short-term outcomes of suction debulking with partial venovenous bypass to conventional open surgery in this population.
Methods: This was a single-center, retrospective study that included all patients with isolated TVIE who underwent suction debulking with partial venovenous bypass or tricuspid valve surgery between January 2010 and December 2022.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!