Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To report the rate of recanalization and the efficacy of punctal occlusion surgery with a high heat-energy-releasing cautery device in patients with severe dry eye disease and recurrent punctal plug extrusion.
Design: Prospective, interventional case series.
Methods: Seventy puncta from 44 eyes of 28 dry eye patients underwent punctal occlusion with thermal cautery. All patients had a history of recurrent punctal plug extrusion. A high heat-energy-releasing thermal cautery device (Optemp II V; Alcon Japan) was used for punctal occlusion surgery. Symptom scores, best-corrected visual acuity, fluorescein staining score, rose bengal staining score, tear film break-up time, and Schirmer test values were compared before and 3 months after the surgery. Rate of punctal recanalization also was examined.
Results: Three months after surgical cauterization, symptom score decreased from 3.9 ± 0.23 to 0.56 ± 0.84 (P < .0001). Logarithm of the minimal angle of resolution best-corrected visual acuity improved from 0.11 ± 0.30 to 0.013 ± 0.22 (P = .003). Fluorescein staining score, rose bengal staining score, tear film break-up time, and the Schirmer test value also improved significantly after the surgery. Only 1 of 70 puncta recanalized after thermal cauterization (1.4%).
Conclusions: Punctal occlusion with the high heat-energy-releasing cautery device not only was associated with a low recanalization rate, but also with improvements in ocular surface wetness and better visual acuity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ajo.2010.08.045 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!