A novel loop-mediated isothermal amplification (LAMP) assay was established to detect Brucella species DNA in milk and blood samples of animals and humans. This LAMP assay based on the sequence of highly repetitive omp25 gene was able to detect 9fg/μl Brucella spp. DNA with high sensitivity, which was 10 times higher than the nested PCR. The LAMP was evaluated for its specificity using 19 strains of six Brucella species and 28 related non-Brucella micro-organism strains as controls. The target 19 Brucella strains were all amplified, and no cross-reaction was found with all the non-Brucella micro-organism strains. Both nested PCR and LAMP assays were then used to detect Brucella spp. DNA in 78 milk samples and 113 blood samples from animals and 11 blood samples from humans, and the established LAMP assay yielded 99.0% concordance rate with the nested PCR. The LAMP assay should be a potential tool with high convenience, rapidity, sensitivity and specificity for the diagnosis of Brucellosis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mcp.2011.01.001DOI Listing

Publication Analysis

Top Keywords

lamp assay
16
brucella spp
12
blood samples
12
nested pcr
12
pcr lamp
12
loop-mediated isothermal
8
isothermal amplification
8
omp25 gene
8
detect brucella
8
brucella species
8

Similar Publications

Multiplex digital nucleic acid analysis (NAA) allows the precise quantification of multiple target nucleic acids with single-molecule sensitivity, making it highly appealing for life science research and clinical diagnostics. Nucleic acid-guided endonucleases, such as CRISPR, have demonstrated great potential in digital NAA. However, performing multiplex digital NAA with an endonuclease remains challenging.

View Article and Find Full Text PDF

Background: Point of need diagnostics provide efficient testing capability for remote or austere locations, decreasing the time to answer by minimizing travel or sample transport requirements. Loop-mediated isothermal amplification (LAMP) is an appealing technology for point-of-need diagnostics due to its rapid analysis time and minimal instrumentation requirements.

Methods: Here, we designed and optimized nine LAMP assays that are sensitive and specific to targeted bacterial select agents including Bacillus anthracis, Francisella tularensis, Yersinia pestis, and Brucella spp.

View Article and Find Full Text PDF

Staphylococcus pseudintermedius is a global animal pathogen. Traditional identification methods are time-consuming necessitating a more efficient approach. This study validated and enhanced the loop-mediated isothermal amplification (LAMP) technique by integration it with a lateral flow dipstick (LFD) assay for the detection of S.

View Article and Find Full Text PDF

Background: The loop-mediated isothermal amplification for TB (TB-LAMP) assay is more cost-effective and accessible than the Xpert MTB/RIF assay. This study aimed to evaluate the diagnostic performance of the TB-LAMP assay in individuals with and without HIV infection.

Methods: Patients aged ≥15 years presenting with symptoms of TB were included in the study.

View Article and Find Full Text PDF

Development of a portable multi-step microfluidic device for point-of-care nucleic acid diagnostics.

Anal Chim Acta

January 2025

State Key Laboratory of Microbial Technology, Microbial Technology Institute, Shandong University, Qingdao, Shandong, 266237, China. Electronic address:

Background: The COVID-19 pandemic has significantly affected global health, economies, and societies, and highlighted the urgent need for rapid, sensitive, affordable, and portable diagnostic devices for respiratory diseases, especially in areas with limited resources. In recent years, there has been rapid development in integrated equipments using microfluidic chips and biochemical detection technologies. However, these devices are expensive and complex to operate, showing limited feasibility for in point of care tests (PoCTs).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!