Aims: According to guidelines, inhaler technique should be tested in all patients, particularly those with poorly controlled asthma. We aimed to assess uncontrolled asthma patients' ability to use a pressurised metered-dose inhaler (pMDI) using the Aerosol Inhalation Monitor (AIM, © Vitalograph).
Methods: Practices invited patients for a detailed clinical review by trained asthma nurses according to practice-agreed protocols. Reviews took place from 1st April to 30th June 2008, and included checking of inhaler technique. Reasons for invitations included, time since last review, asthma control, prescriptions, adherence to medical advice. A proxy measure of control--the total number of short-acting β2-agonist (SABA) bronchodilator inhaler canisters prescribed in the previous 12 months--was used. Data on 77 pre-determined clinical parameters (including prescribing and healthcare utilisation data) were collected. Patient-completed postal symptom questionnaires (the RCP 3 questions) were obtained in some patients. All patients using pMDIs had at least two assessments using the AIM, and where appropriate inhaler technique education was provided.
Results: 2123 (24% of those invited) symptomatic asthma patients were reviewed; 1291 (61%) were using pMDIs (mean age 52 years; SD 21), of whom over 80% were in BTS/SIGN Steps 2 and 3. 1092 (85.6%) of those patients using pMDIs failed the first AIM assessment. There was a significant increase in the number of patients able to use their pMDIs correctly following instruction after the second (129 to 260 of 1197 patients, p<0.01) and third (61 to 181 of 528 patients, p< 0.01) tests. However, 78.4% and 65.7% of those tested twice and three times, respectively, failed the AIM assessment despite instruction. Logistic regression analysis failed to show any effect of age and BTS step on these outcomes.
Conclusions: A majority of symptomatic asthma patients in this study were unable to use pMDIs correctly. It is essential to check all patients' ability to use their prescribed inhalers regularly. Cost alone should not determine prescribing recommendations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6549799 | PMC |
http://dx.doi.org/10.4104/pcrj.2010.00088 | DOI Listing |
Paediatr Anaesth
January 2025
Department of Anesthesiology, Duke University School of Medicine, Duke University Medical Center, Durham, North Carolina, USA.
Background: In pediatric patients, the use of processed EEG monitoring may reduce the amount of anesthesia administered while maintaining adequate depth of anesthesia.
Aims: The primary aim of this study was to evaluate whether use of a BIS monitor to guide sevoflurane administration might reduce the average end tidal sevoflurane concentration used in children 4-18 years of age.
Methods: Participants in three age groups (4-8, 9-12, and 13-18 years) were randomized to either the BIS guided group or the control group.
Animal Model Exp Med
January 2025
National Research Centre for the Working Environment, Copenhagen, Denmark.
Background: Inhalation exposure is the gold standard when assessing pulmonary toxicity. However, it typically requires substantial amounts of test material. Intratracheal instillation is an alternative administration technique, where the test substance is suspended in a liquid vehicle and deposited into the lung via the trachea.
View Article and Find Full Text PDFPediatr Nephrol
January 2025
Pediatric Nephrology, Faculty of Medicine, Ankara City Hospital, Ankara Yıldırım Beyazıt University Ankara, Bilkent, Turkey.
Background: Studies suggest that asthma and hypertension may be comorbid conditions. Most of these studies are epidemiological research. However, data on the relationship between asthma and hypertension in childhood are limited.
View Article and Find Full Text PDFInt J Surg Case Rep
January 2025
Department of Pediatric Surgery, The University of Child Health Sciences and The Children's Hospital, Lahore, Lahore - Kasur Rd, Nishtar Town, Lahore, Punjab, Pakistan 54000.
Introduction: Foreign body (FB) inhalation is a potentially life-threatening condition in children. Magnets, being rare, aspirated objects, pose significant threat due to their physical and magnetic properties.
Case Presentation: A 10-year-old girl with a history of magnet aspiration went into respiratory distress due to dislodgement of magnet to opposite main bronchus following failed attempt of removal via Rigid Bronchoscopy.
Environ Geochem Health
January 2025
Nuclear Technology Research and Development Center, Thailand Institute of Nuclear Technology, Nakhon Nayok, 26120, Thailand.
The present study aimed to investigate the hydrogeochemical patterns and contamination of the radiogeology, especially radon activity, related to geothermal aquifer properties and to perform a risk assessment of annual effective doses covering all hydrothermal spring attractions in Southern Thailand. Radon is an established lung carcinogen; especially longer term exposure to radioactive radon through inhalation could be a cause of lung cancer risk. Altogether 22 hydrothermal spring samples were collected from the six hydrothermal provinces in Southern Thailand in early November of 2023.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!