The purpose of this article is to underline the possibility of efficiently using electron ionization (EI) in liquid chromatography (LC) and mass spectrometry (MS). From a historical perspective, EI accompanied the first attempts in LC-MS but, owing to several technical shortcomings, it was soon outshined by soft, atmospheric pressure ionization (API) techniques. Nowadays, two modern approaches, supersonic molecular beam LC-MS and direct-EI LC-MS, offer a valid alterative to API, and preserve the advantages of EI also in LC-MS applications. These advantages can be summarized in three crucial aspects: automated library identification; identification of unknown compounds, owing to EI extensive fragment information; inertness to coeluted matrix interferences owing to very unlikely ion-ion and ion-molecule interactions in the EI gas-phase environment. The direct-EI LC-MS interface is a simple and efficient solution able to produce high-quality, interpretable EI spectra from a wide range of low molecular weight molecules of different polarity. Because of the low operative flow rates, this interface relies on a nano-LC technology that helps in reducing the impact of the mobile phase on the gas-phase environment of EI. This review provides an extensive discussion on the role of EI in LC-MS interfacing, and presents in detail several performance aspects of the direct-EI LC-MS interface, especially in terms of response, mass-spectral quality, and matrix effects. In addition, several key applications are also reported.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-010-4637-0DOI Listing

Publication Analysis

Top Keywords

direct-ei lc-ms
16
lc-ms interface
12
lc-ms
9
electron ionization
8
gas-phase environment
8
ionization lc-ms
4
lc-ms developments
4
developments applications
4
direct-ei
4
applications direct-ei
4

Similar Publications

Although LC-MS with atmospheric pressure ionization (API) sources is the primary technique used in modern bioanalytical studies, electron ionization mass spectrometry (EI-MS) can provide some substantial advantages over it. EI-MS is a matrix effect-free technique that provides reproducible and comparable mass spectra, serving as a compound fingerprint for easy identification through automated comparison with spectral libraries. Leveraging EI-MS in biochemical studies can yield critical analytical benefits for targeted and untargeted analyses.

View Article and Find Full Text PDF

This is the first application based on electron ionization (EI) using a Direct-EI LC interface and MS/MS to detect unequivocally target compounds in a very small real sample. The determination and quantification of benzodiazepines in very small residues of beverages, collected at the scene of drug-facilitated crimes are mandatory in legal procedures. A specific and sensitive analytical instrumentation is needed, involving little or no sample preparation.

View Article and Find Full Text PDF

The purpose of this article is to underline the miniaturized LC instrumental system and describe the evolution of commercially available systems by discussing their advantages and drawbacks. Nowadays, there are already many miniaturized LC systems available with a great variety of pump design, interface and detectors as well as efficient columns technologies and reduced connections devices. The solvent delivery systems are able to drive the mobile phase without flow splitters and promote gradient elution using either dual piston reciprocating or syringe-type pumps.

View Article and Find Full Text PDF

An LC-MS method for the analysis of personal care and household products without sample preparation is presented. The method takes advantage of the Direct-electron ionization (EI) LC-MS interface for the quantitation of principal components, as well as for the identification of unknown or undeclared ingredients. The technique has proven its inertness toward matrix effects and the electron ionization allows quantitation and library identification.

View Article and Find Full Text PDF

We investigated the effect of temperature on the packing procedure of nano-LC columns (up to 50 cm) and on their performance. Several slurries of stationary phase were prepared using different solvent mixtures. Their stability was evaluated at several temperatures: 70°C, 50°C, and room temperature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!