Background: HIV-1 is characterized by increased genetic heterogeneity which tends to hinder the reliability of detection and accuracy of HIV-1 RNA quantitation assays.
Methods: In this study, the Abbott RealTime HIV-1 (Abbott RealTime) assay was compared to the Roche Cobas TaqMan HIV-1 (Cobas TaqMan) and the Siemens Versant HIV-1 RNA 3.0 (bDNA 3.0) assays, using clinical samples of various viral load levels and subtypes from Greece, where the recent epidemiology of HIV-1 infection has been characterized by increasing genetic diversity and a marked increase in subtype A genetic strains among newly diagnosed infections.
Results: A high correlation was observed between the quantitative results obtained by the Abbott RealTime and the Cobas TaqMan assays. Viral load values quantified by the Abbott RealTime were on average lower than those obtained by the Cobas TaqMan, with a mean (SD) difference of -0.206 (0.298) log(10) copies/ml. The mean differences according to HIV-1 subtypes between the two techniques for samples of subtype A, B, and non-A/non-B were 0.089, -0.262, and -0.298 log(10) copies/ml, respectively. Overall, differences were less than 0.5 log(10) for 85% of the samples, and >1 log(10) in only one subtype B sample. Similarly, Abbott RealTime and bDNA 3.0 assays yielded a very good correlation of quantitative results, whereas viral load values assessed by the Abbott RealTime were on average higher (mean (SD) difference: 0.160 (0.287) log(10) copies/ml). The mean differences according to HIV-1 subtypes between the two techniques for subtype A, B and non-A/non-B samples were 0.438, 0.105 and 0.191 log(10) copies/ml, respectively. Overall, the majority of samples (86%) differed by less than 0.5 log(10), while none of the samples showed a deviation of more than 1.0 log(10).
Conclusions: In an area of changing HIV-1 subtype pattern, the Abbott RealTime assay showed a high correlation and good agreement of results when compared both to the Cobas TaqMan and bDNA 3.0 assays, for all HIV-1 subtypes tested. All three assays could determine viral load from samples of different HIV-1 subtypes adequately. However, assay variation should be taken into account when viral load monitoring of the same individual is assessed by different systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3032708 | PMC |
http://dx.doi.org/10.1186/1743-422X-8-10 | DOI Listing |
J Pathol Inform
January 2025
Harvard Medical School, Boston, MA, United States of America.
Objective: Thrombocytopenia is a common complication of hematopoietic stem-cell transplantation (HSCT), though many patients will become immune refractory to platelet transfusions over time. We built and evaluated an electronic health record (EHR)-integrated, standards-based application that enables blood-bank clinicians to match platelet inventory with patients using data previously not available at the point-of-care, like human leukocyte antigen (HLA) data for donors and recipients.
Materials And Methods: The web-based application launches as an EHR-embedded application or as a standalone application.
BMJ Open Diabetes Res Care
December 2024
The Australian Centre for Behavioural Research in Diabetes, Diabetes Victoria, Carlton, Victoria, Australia.
Introduction: This analysis aimed to investigate diabetes-specific psychological outcomes among adults with type 1 diabetes (T1D) using hybrid closed-loop (HCL) versus standard therapy.
Research Design And Methods: In this multicenter, open-label, randomized, controlled, parallel-group clinical trial, adults with T1D were allocated to 26 weeks of HCL (MiniMedâ„¢ 670G) or standard therapy (insulin pump or multiple daily injections without real-time continuous glucose monitoring). Psychological outcomes (awareness and fear of hypoglycemia; and diabetes-specific positive well-being, diabetes distress, diabetes treatment satisfaction, and diabetes-specific quality of life (QoL)) were measured at enrollment, mid-trial and end-trial.
JTCVS Open
December 2024
Department of Cardiac Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Mass.
Background: Perioperative right ventricular (RV) dysfunction is associated with increased morbidity and mortality in cardiac surgery patients. This study aimed to demonstrate proof of concept in generating intraoperative RV pressure-volume (PV) loops and conducting an end-systolic PV relationship (ESPVR) analysis using data obtained from routinely used intraoperative monitors.
Methods: Adult patients undergoing cardiac surgery with the placement of a pulmonary artery catheter (PAC) between May 2023 and March 2024 were included prospectively.
Viruses
December 2024
Department of Medicine & State Key Laboratory of Liver Research, School of Clinical Medicine, The University of Hong Kong, Hong Kong, China.
Full-length hepatitis B virus (HBV) transcripts of chimpanzees and patients treated with multidose (MD) HBV siRNA ARC-520 and entecavir (ETV) were characterized by single-molecule real-time (SMRT) sequencing, identifying multiple types of transcripts with the potential to encode HBx, HBsAg, HBeAg, core, and polymerase, as well as transcripts likely to be derived from dimers of dslDNA, and these differed between HBeAg-positive (HBeAg+) and HBeAg-negative (HBeAg-) individuals. HBV transcripts from the last follow-up ~30 months post-ARC-520 treatment were categorized from one HBeAg+ (one of two previously highly viremic patients that became HBeAg- upon treatment and had greatly reduced cccDNA products) and four HBeAg- patients. The previously HBeAg+ patient received a biopsy that revealed that he had 3.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!