An efficient calix[4]arene based silica sorbent for the removal of endosulfan from water.

J Hazard Mater

Dr. M. A. Kazi Institute of Chemistry, University of Sindh, Jamshoro 76080, Pakistan.

Published: February 2011

The present work explores sorption behavior of calix[4]arene based silica resin to remove α and β endosulfan isomers from aqueous solution. The efficiency of resin was checked through both batch and column sorption methods. In both methods, the sorption parameters, i.e. pH, equilibrium time, shaking speed and sorbent dosage were optimized as 2, 60 min, 125 rpm and 50 mg, respectively. Freundlich and Langmuir sorption isotherm models were applied to validate the sorption process. The data obtained in both models reveal that the sorption is favorable. Column sorption data were analyzed through Thomas model to calculate kinetic coefficient k(TH) and maximum sorption capacity q(o) of the resin, which were found to be 6.18 and 5.83 cm(3) mg(-1) min(-1) as well as 1.11 and 1.08 mg g(-1) for α and β endosulfan, respectively. Kinetics of sorption shows that it follows pseudo second order rate equation. The optimized method has also been applied to real water samples and the results show that calix[4]arene based silica resin is an effective sorbent to remove endosulfan from waste waters.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhazmat.2010.12.048DOI Listing

Publication Analysis

Top Keywords

calix[4]arene based
12
based silica
12
sorption
9
silica resin
8
remove endosulfan
8
column sorption
8
efficient calix[4]arene
4
silica sorbent
4
sorbent removal
4
endosulfan
4

Similar Publications

Para-acyl-calix-arene based solid lipid nanoparticles (SLNs): a detailed study of preparation and stability parameters.

Int J Pharm

March 2003

Institut de Biologie et Chimie des Protéines, CNRS UMR 5086, 7 Passage du Vercors, F-69367 Lyon Cedex 07, France.

The preparation and stability parameters of para-acyl-calix[4]arene based solid lipid nanoparticles (SLNs) have been investigated. Atomic force microscopy (AFM) and photon correlation spectroscopy (PCS) show a mean particle size of 130 nm. In terms of preparation parameters, using the solvent displacement method, the nature and the volume of the organic solvent, the concentration of the amphiphile and the presence of a co-surfactant in the organic phase have been shown to affect significantly the size of the produced SLNs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!