A perfusion electrodeposition (P-ELD) system was reported to functionalize additive manufactured Ti6Al4V scaffolds with a calcium phosphate (CaP) coating in a controlled and reproducible manner. The effects and interactions of four main process parameters - current density (I), deposition time (t), flow rate (f) and process temperature (T) - on the properties of the CaP coating were investigated. The results showed a direct relation between the parameters and the deposited CaP mass, with a significant effect for t (P=0.001) and t-f interaction (P=0.019). Computational fluid dynamic analysis showed a relatively low electrolyte velocity within the struts and a high velocity in the open areas within the P-ELD chamber, which were not influenced by a change in f. This is beneficial for promoting a controlled CaP deposition and hydrogen gas removal. Optimization studies showed that a minimum t of 6 h was needed to obtain complete coating of the scaffold regardless of I, and the thickness was increased by increasing I and t. Energy-dispersive X-ray and X-ray diffraction analysis confirmed the deposition of highly crystalline synthetic carbonated hydroxyapatite under all conditions (Ca/P ratio=1.41). High cell viability and cell-material interactions were demonstrated by in vitro culture of human periosteum derived cells on coated scaffolds. This study showed that P-ELD provides a technological tool to functionalize complex scaffold structures with a biocompatible CaP layer that has controlled and reproducible physicochemical properties suitable for bone engineering.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.actbio.2010.12.032 | DOI Listing |
ACS Appl Mater Interfaces
August 2024
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China.
Temperature has a profound influence on various neuromodulation processes and has emerged as a focal point. However, the effects of acute environmental temperature fluctuations on cultured cortical networks have been inadequately elucidated. To bridge this gap, we have developed a brain-on-a-chip platform integrating cortical networks and electrodeposited Pt/Ir modified microelectrode arrays (MEAs) with 3D-printed bear-shaped triple chambers, facilitating control of temperature transients.
View Article and Find Full Text PDFJ Biomater Appl
March 2023
School of Advanced Medical Sciences and Technologies, 48435Shiraz University of Medical Sciences, Shiraz, Iran.
Limitations in liver transplantation and advances in cell therapy methods motivated us to study primary hepatocytes. The main challenge in using primary hepatocytes for liver regeneration is that they lose their functionalities. We aimed to develop a controlled-shape hydrogel and apply the conditioned-media of mesenchymal stromal cells (CM-MSCs) to improve in vitro hepatocyte functions.
View Article and Find Full Text PDFJ Mater Sci Mater Med
February 2015
Department of Vascular Surgery, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing, 100053, China.
Studies on three-dimensional tissue engineered graft (3DTEG) have attracted great interest among researchers as they present a means to meet the pressing clinical demand for tissue engineering scaffolds. To explore the feasibility of 3DTEG, high porosity poly-ε-caprolactone (PCL) was obtained via the co-electrospinning of polyethylene glycol and PCL, and used to construct small-diameter poly-ε-caprolactone-lysine (PCL-LYS-H) scaffolds, whereby heparin was anchored to the scaffold surface by lysine groups. A variety of small-diameter 3DTEG models were constructed with different PCL layers and the mechanical properties of the resulting constructs were evaluated in order to select the best model for 3DTEGs.
View Article and Find Full Text PDFBiomaterials
June 2012
Laboratory for Skeletal Development and Joint Disorders, KU Leuven, O&N 1, Herestraat 49, Bus 813, 3000 Leuven, Belgium.
Successful clinical repair of non-healing skeletal defects requires the use of bone substitutes with robust bone inductivity and excellent biomechanical stability. Thus, three-dimensionally functionalised porous calcium phosphate-Ti6Al4V (CaP-Ti) hybrids were produced by perfusion electrodeposition, and the in vitro and in vivo biological performances were evaluated using human periosteum derived cells (hPDCs). By applying various current densities at the optimised deposition conditions, CaP coatings with sub-micrometer to nano-scale porous crystalline structures and different ion dissolution kinetics were deposited on the porous Ti6Al4V scaffolds.
View Article and Find Full Text PDFActa Biomater
May 2011
Laboratory for Skeletal Development and Joint Disorders, Katholieke Universiteit Leuven, Belgium.
A perfusion electrodeposition (P-ELD) system was reported to functionalize additive manufactured Ti6Al4V scaffolds with a calcium phosphate (CaP) coating in a controlled and reproducible manner. The effects and interactions of four main process parameters - current density (I), deposition time (t), flow rate (f) and process temperature (T) - on the properties of the CaP coating were investigated. The results showed a direct relation between the parameters and the deposited CaP mass, with a significant effect for t (P=0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!