We report wide-ranging studies to elucidate the factors and issues controlling stripping voltammetry of metal ions on solid electrodes using the well-known Pb/Pb(2+) couple on polycrystalline boron doped diamond (pBDD) as an exemplar system. Notably, high-resolution microscopy techniques have revealed new insights into the features observed in differential pulse anodic stripping voltammetry (DPV-ASV) which provide a deeper understanding of how best to utilize this technique. DPV-ASV was employed in an impinging wall-jet configuration to detect Pb(2+) in the nanomolar to micromolar concentration range at a pBDD macrodisk electrode. The deposition process was driven to produce a grain-independent homogeneous distribution of Pb nanoparticles (NPs) on the electrode surface; this resulted in the observation of narrow stripping peaks. Lower calibration gradients of current or charge versus concentration were found for the low concentrations, correlating with a lower than expected (from consideration of the simple convective-diffusive nature of the deposition process) amount of Pb deposited on the surface. This was attributed to the complex nature of nucleation and growth at solid surfaces in this concentration regime, complicating mass transport. Furthermore, a clear shift negative in the stripping peak potential with decreasing concentration was seen correlating with a change in the size of the deposited NP, suggesting an NP size-dependent redox potential for the Pb/Pb(2+) couple. At high concentrations a nonlinear response was observed, with less Pb detected than expected, in addition to the observation of a second stripping peak. Atomic force microscopy (AFM) and field emission scanning electron microscopy revealed the second peak to be due to a change in deposition morphology from isolated NPs to grain-independent heterogeneous structures comprising both thin films and NPs; the second peak is associated with stripping from the thin-film structures. AFM also revealed a substantial amount of Pb remaining on the surface after stripping at high concentration, explaining the nonlinear relationship between stripping peak current (or charge) and concentration. Finally, the use of an in situ cleaning procedure between each measurement was advocated to ensure a clean Pb-free surface (verified by AFM and X-ray photoelectron spectroscopy analysis) between each run. The studies herein highlight important and complex physicochemical processes involved in the electroanalysis of heavy metals at solid electrodes, such as pBDD, that need to be accounted for when using stripping voltammetry methods.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ac101626s | DOI Listing |
Heliyon
July 2024
Engineering Faculty, Department of Environmental and Chemical Engineering, Universidad Nacional de Colombia, Colombia.
In the present work, we report the synthesis and evaluation of a graphite-supported bismuth film working electrode (BiFE) in the simultaneous quantification of Hg(II) and Pb(II) at ppb levels. The BiFE was synthesized in-situ by electrodeposition in 1 M HNO as the supporting electrolyte at -0.5 V potential.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
Department of Chemistry and Applied Biosciences, Laboratory of Inorganic Chemistry, ETH Zürich, Vladimir-Prelog-Weg 1-5/10, Zürich, CH-8093, Switzerland; Laboratory of Radiochemistry, Centre for Nuclear Engineering and Sciences, Paul Scherrer Institute, Forschungsstrasse 111, Villigen PSI, CH-5232, Switzerland. Electronic address:
Background: The direct and accurate measurement of low-level γ-emitters in samples from nuclear facilities is a challenging task due to the presence of high activities of dominant radionuclides. In this case a complex chemical separation is required to remove interfering radionuclides prior to γ-spectrometric analysis. Several radionuclides such as, Ag, Sb, Sn and Te are of relevance for radioanalytical analysis in nuclear facilities.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Technical Faculty in Bor, University of Belgrade, Vojske Jugoslavije 12, P.O. Box 50, 19210 Bor, Serbia.
Cadmium is one of the most dangerous pollutants found in the environment, where it exists mainly due to human activities. High cadmium concentrations can cause serious problems, which is why the detection and determination of Cd is one of the most important tasks. Electroanalytical methods provide rapid and accurate results in the detection of cadmium in various solutions.
View Article and Find Full Text PDFJ Colloid Interface Sci
December 2024
Department of Materials Science and Engineering, National Tsing Hua University, Hsinchu 300044, Taiwan; High Entropy Materials Center, Hsinchu 300044, Taiwan. Electronic address:
LiAlTi (PO) (LATP) is a promising NASICON-type solid electrolyte for all-solid-state lithium-ion batteries (ASSLIBs) owing to its high ionic conductivity, low cost, and stability in ambient atmosphere. However, the electrochemical stability of LATP suffers upon contact with lithium metals, resulting in a reduction of Ti to Ti in its structure. This limitation necessitates interface modification processes, hindering its use in lithium-ion batteries.
View Article and Find Full Text PDFAnal Chem
January 2025
Laboratory of Analytical Chemistry, Department of Chemistry, University of Athens, Athens 157 71, Greece.
This work describes fully integrated multifolding electrochemical paper-based devices (ePADs) for enhanced multiplexed voltammetric determination of heavy metals (Zn(II), Cd(II), and Pb(II)) using tunable passive preconcentration. The paper devices integrate five circular sample preconcentration layers and a 3-electrode electrochemical cell. The hydrophobic barriers of the devices are drawn by pen-plotting with hydrophobic ink, while the electrodes are deposited by screen-printing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!