Alignment and calibration of dual ultrasound transducers using a wedge phantom.

Ultrasound Med Biol

Department of Mechanical Engineering, University of British Columbia, Vancouver, BC, Canada.

Published: February 2011

AI Article Synopsis

  • A new method helps align two ultrasound transducers into one scan plane using a wedge phantom for visual feedback.
  • Calibration techniques ensure the transducers are correctly aligned, with errors kept below 1° in rotation and 1 mm in translation after multiple adjustments.
  • This dual transducer system is effective for imaging soft tissues like the breast and can enhance image quality through techniques like spatial compounding.

Article Abstract

We present a novel method of aligning two orthogonal ultrasound transducers into a coincident scan plane. A wedge phantom design provides visual feedback to the user to facilitate alignment. Calibration provides the transformation from one transducer to the other as well as a measure of the residual error in alignment. Mean alignment error is shown to be under 1° in the rotation axes and 1 mm in translation after repeated manual alignments. The repeatability of wedge based calibration has similar results compared with N-fiducial based calibration. The accuracy of the calibration for mapping points from one transducer to the other is found to have a mean error of 1.6 mm. The dual transducer system is well suited to imaging anatomy such as the breast and may be used for spatial compounding for improving B-mode images and motion estimation compounding for improving elastography results.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2010.10.025DOI Listing

Publication Analysis

Top Keywords

alignment calibration
8
ultrasound transducers
8
wedge phantom
8
based calibration
8
compounding improving
8
alignment
4
calibration dual
4
dual ultrasound
4
transducers wedge
4
phantom novel
4

Similar Publications

In the field of industrial measurement, capturing a three-dimensional (3D) profile of an annular inner-wall has been a significant challenge. Current methods typically require multiple scans using a 3D scanner or circular structured light technique, which are inefficient and inconvenient to use. To address this issue, an off-axis measurement method and corresponding system has been proposed in this paper based on circular fringe projection.

View Article and Find Full Text PDF

In the realm of 3D measurement, photometric stereo excels in capturing high-frequency details but suffers from accumulated errors that lead to low-frequency distortions in the reconstructed surface. Conversely, light field (LF) reconstruction provides satisfactory low-frequency geometry but sacrifices spatial resolution, impacting high-frequency detail quality. To tackle these challenges, we propose a photometric stereoscopic light field measurement (PSLFM) scheme that harnesses the strengths of both methods.

View Article and Find Full Text PDF

Revising the coal mining CH emission factor based on multiple inventories and atmospheric inversion approach at one of the world's largest coal production areas: Shanxi province, China.

Sci Total Environ

January 2025

College of Ecology and Environment, Joint Center for sustainable Forestry in Southern China, Nanjing Forestry University, Nanjing 210037, China; Yale-NUIST Center on Atmospheric Environment, Collaborative Innovation Center on Forecast and Evaluation of Meteorological Disasters (CIC-FEMD), Nanjing University of Information Science & Technology, Nanjing 210044, China. Electronic address:

Methane (CH) emissions from the coal industry represent a substantial portion of anthropogenic CH emissions from energy-related activities. China ranks as the world's largest coal producer, where Shanxi Province is one of its major coal production regions and accounts for 20.7 % of the national total coal production.

View Article and Find Full Text PDF

This study developed a scientific process parameter setup based on nozzle pressure and screw position, with the process parameter search sequence being injection speed, / switchover position, packing pressure, and packing time. Unlike previous studies, this study focuses on the scientific process parameter setup of experiments and simulations, as well as on the implementation of calibration. Experiments and simulations had the same trend of results in the scientific process parameter setup.

View Article and Find Full Text PDF

The Application of Supervised Machine Learning Algorithms for Image Alignment in Multi-Channel Imaging Systems.

Sensors (Basel)

January 2025

Department of Computer-Integrated Technologies of Device Production, Faculty of Instrumentation Engineering, National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute", Beresteiskyi Ave., 37, 03056 Kyiv, Ukraine.

This study presents a method for aligning the geometric parameters of images in multi-channel imaging systems based on the application of pre-processing methods, machine learning algorithms, and a calibration setup using an array of orderly markers at the nodes of an imaginary grid. According to the proposed method, one channel of the system is used as a reference. The images from the calibration setup in each channel determine the coordinates of the markers, and the displacements of the marker centers in the system's channels relative to the coordinates of the centers in the reference channel are then determined.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!