Background: A percutaneously placed, totally intravascular defibrillator has been developed that shocks via a right ventricular (RV) single-coil and titanium electrodes in the superior vena cava (SVC) and the inferior vena cava (IVC). This study evaluated the defibrillation threshold (DFT) with this electrode configuration to determine the effect of different biphasic waveform tilts and second-phase durations as well as the contribution of the IVC electrode.
Methods: Eight Bluetick hounds (wt = 30-40 kg) were anesthetized and the RV coil (first-phase anode) was placed in the RV apex. The intravascular defibrillator (PICD®, Model no. IIDM-G, InnerPulse Inc., Research Triangle Park, NC, USA) was positioned such that the titanium electrodes were in the SVC and IVC . Ventricular fibrillation was electrically induced and a Bayesian up-down technique was employed to determine DFT with two configurations: RV to SVC + IVC and RV to SVC. Three waveform tilts (65%, 50%, and 42%) and two second-phase durations (equal to the first phase [balanced] and truncated at 3 ms [unbalanced]) were randomly tested. The source capacitance of the defibrillator was 120 μF for all waveforms.
Results: DFT with the IVC electrode was significantly lower than without the IVC electrode for all waveforms tested (527 ± 9.3 V [standard error], 14.5 J vs 591 ± 7.4 V, 18.5 J, P < 0.001). Neither waveform tilt nor second-phase duration significantly changed the DFT.
Conclusion: In canines, a totally intravascular implantable defibrillator with electrodes in the RV apex, SVC, and IVC had a DFT similar to that of standard nonthoracotomy lead systems. No significant effect was noted with changes in tilt or with balanced or unbalanced waveforms.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1540-8159.2010.03006.x | DOI Listing |
J Clin Med
December 2024
Venous Thromboembolism Unit, Internal Medicine Department, Hospital General Universitario Gregorio Marañón, 28007 Madrid, Spain.
Catheter-related thrombosis (CRT) is a frequent and potentially serious complication associated with the widespread use of intravascular devices such as central venous catheters, including peripherally inserted central catheters and implantable port systems, pacemakers or implantable cardioverter-defibrillators. Although CRT management has been informed by guidelines extrapolated from lower extremity deep vein thrombosis (DVT), unique challenges remain due to the distinct anatomical, pathophysiological, and clinical characteristics of upper extremity DVT. Risk factors for CRT are multifactorial, encompassing patient-related characteristics such as cancer, prior venous thromboembolism, and infection, as well as catheter-specific factors like device type, lumens, and insertion site.
View Article and Find Full Text PDFCard Electrophysiol Clin
December 2024
Division of Electrophysiology, Department of Cardiac Health, Southlake Regional Health Center, 602-581 Davis Drive, Newmarket, ON L3Y 2P6, Canada. Electronic address:
Transvenous lead extraction is performed for device infection, lead failure, or to provide access for additional leads/device upgrade. A patient-centered risk assessment for transvenous lead extraction can be determined using a combination of clinical factors and several imaging modalities. Predicting a complex lead extraction, for example, one that will require powered tools or the use of a femoral approach, is aided by pre-procedural imaging and clinical assessment.
View Article and Find Full Text PDFHeartRhythm Case Rep
September 2024
Knight Cardiovascular Institute, Oregon Health and Sciences University, Portland, Oregon.
For several years, implantable cardioverter defibrillators (ICDs) have been the cornerstone for the prevention of sudden cardiac death. However, the weakness of traditional transvenous ICD systems lies in the intravascular lead, which is prone to issues such as conductor fracture, insulation abrasion, risk of dislodgement, and infection. With the new generation of subcutaneous defibrillators, these risks are far less common.
View Article and Find Full Text PDFCureus
August 2024
Anesthesiology and Perioperative Care, UCI Health, Orange, USA.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!